Systematic errors and susceptibility to noise of four methods for calculating anatomical dead space from the CO2 expirogram.
نویسندگان
چکیده
BACKGROUND Anatomical dead space is usually measured using the Fowler equal area method. Alternative methods include the Hatch, Cumming, and Bowes methods, in which first, second, and third order polynomials, respectively, fitted to an expired CO2 volume vs expired volume curve, intercept the x-axis at the anatomical dead space. This study assessed systematic errors and susceptibility to noise of the Fowler, Hatch, Cumming, and Bowes dead spaces calculated over 40-80% of the CO2 expirogram. METHODS Simulated CO2 expirograms with 220 ml anatomical dead space and varying alveolar plateau slopes were generated digitally and zero-mean Gaussian noise added. CO2 expirograms were recorded in 10 anaesthetized human subjects. Anatomical dead space was calculated by the Fowler, Hatch, Cumming, and Bowes methods. RESULTS The Fowler, Hatch, Cumming, and Bowes methods displayed systematic biases of -1.8%, 13.2%, 2.4%, and -1.3%, respectively, at a normalized simulated alveolar plateau slope of 1.6 litre(-1). At a noise level of 0.0066 vol/vol, the standard deviations of recovered simulated dead spaces were 70.6, 1.8, 2.4, and 3.7 ml, respectively. The Hatch, Cumming, and Bowes methods applied to human expirograms differed significantly from that of Fowler by 13, -4, and -11 ml, respectively. In the human study, the Hatch and Cumming methods yielded the lowest intra-individual dead space variability. CONCLUSIONS The Fowler method shows greatest susceptibility to measurement noise and the Hatch method exhibits the largest systematic error. The Cumming method, which exhibits both low bias and low noise susceptibility, is preferred for estimating anatomical dead space from CO2 expirograms.
منابع مشابه
Comparison of Two Quantitative Susceptibility Mapping Measurement Methods Used For Anatomical Localization of the Iron-Incorporated Deep Brain Nuclei
Introduction Quantitative susceptibility mapping (QSM) is a new contrast mechanism in magnetic resonance imaging (MRI). The images produced by the QSM enable researchers and clinicians to easily localize specific structures of the brain, such as deep brain nuclei. These nuclei are targets in many clinical applications and therefore their easy localization is a must. In this study, we aimed to i...
متن کاملThe Diagnostic Value of End-tidal Carbon Dioxide (EtCO2) and Alveolar Dead Space (AVDS) in Patients with Suspected Pulmonary Thrombo-embolism (PTE)
Introduction: Capnography, is an easy, fast and practical method which its application in the diagnosis of Pulmonary Thromboendarterectomy (PTE) has recently been studied. This study aimed to assess the diagnostic value of end-tidal CO2 (ETCO2) and the alveolar dead space (AVDS) in the diagnosis of patients suspected to PTE who have been referred to the emergency department. Materials and Metho...
متن کاملExposure to Chronic Noise Reduces the Volume of Hippocampal Subregions in Rats
Objective The hippocampal circuit integrity is crucial for learning and memory. Despite the existing reports on hippocampal–dependent memory impairment due to noise stress, there are only a few studies on the effect of noise stress on anatomical structure of hippocampus. The present study is aimed to investigate the likely effects of chronic noise exposure on the volume of rat hippocampus. Mate...
متن کاملApplication of CO2 waveform in the alveolar recruitment maneuvers of hypoxemic patients during one-lung ventilation
Deterioration of gas exchange during one-lung ventilation (OLV) is caused by both total collapse of the nondependent lung and partial collapse of the dependent lung. Alveolar recruitment maneuver improves lung function during general anesthesia. The objective of this study was to investigate whether there is an indirect relationship between the changes of CO2 expirogram and the selective lung r...
متن کاملApplication of Single-Frequency Time-Space Filtering Technique for Seismic Ground Roll and Random Noise Attenuation
Time-frequency filtering is an acceptable technique for attenuating noise in 2-D (time-space) and 3-D (time-space-space) reflection seismic data. The common approach for this purpose is transforming each seismic signal from 1-D time domain to a 2-D time-frequency domain and then denoising the signal by a designed filter and finally transforming back the filtered signal to original time domain. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 98 6 شماره
صفحات -
تاریخ انتشار 2007