Detection of periodontal bone loss using digital intraoral and cone beam computed tomography images: an in vitro assessment of bony and/or infrabony defects.

نویسندگان

  • B Vandenberghe
  • R Jacobs
  • J Yang
چکیده

OBJECTIVES To explore the diagnostic values of digital intraoral radiography and cone beam CT (CBCT) in the determination of periodontal bone loss, infrabony craters and furcation involvements. METHODS Accuracy assessment of the imaging modalities was conducted through bone level measurements, infrabony crater and furcation involvement classifications. For CBCT, images were obtained at 120 kV and 23.87 mAs, and observations were made on a 5.2 mm panoramic reconstruction view and on 0.4 mm thick cross-sectional slices. Intraoral radiographs of a size 2 charge-coupled device (CCD) sensor were obtained using the paralleling technique, at 60 kV (DC) and 0.28 mAs exposure. 71 human cadaver and dry skull bony defects were measured and evaluated by 3 observers. Comparison was made with the gold standard. RESULTS The mean error (gold standard deviation) of bone level measurements was 0.56 mm for intraoral radiography and 0.47 mm for the CBCT panoramic 5.2 mm reconstruction view. There were no significant differences (P = 0.165) between the two methods. However, on 0.4 mm thick cross-sections, the mean error was 0.29 mm and the Wilcoxon signed-rank test indicated a significant difference when compared with the CCD (P = 0.006). The detection of crater and furcation involvements failed in 29% and 44% for the CCD, respectively, in contrast to 100% detectability for both defects with CBCT. CONCLUSIONS CBCT on the panoramic 5.2 mm reconstruction view allowed comparable measurements of periodontal bone levels and defects as with intraoral radiography. CBCT with 0.4 mm thick cross-sections demonstrated values closer to the gold standard, indicating more accurate assessment of periodontal bone loss. Further research is needed to explore these results in vivo and to determine the use of CBCT in periodontal diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.  Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

بررسی مقایسه‌ای دقت Cone beam CT، رادیوگرافی داخل دهانی و پروب پریودنتال در اندازه‌گیری ضایعات استخوانی پریودنتال

Background and Aims: Cone beam computed tomography (CBCT) produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods.Materials and Methods: Two-hundred a...

متن کامل

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

Comparison of intraoral radiography and cone-beam computed tomography for the detection of periodontal defects: an in vitro study

BACKGROUND This study aimed to compare the diagnostic accuracy of cone-beam computed tomography (CBCT) unit with digital intraoral radiography technique for detecting periodontal defects. METHODS The study material comprised 12 dry skulls with maxilla and mandible. Artificial defects (dehiscence, tunnel, and fenestration) were created on anterior, premolar and molar teeth separately using bur...

متن کامل

بررسی ارتباط بین ضخامت مخاط سینوس ماگزیلاری و با استفاده از periodontal bone loss Cone beam computed tomography

Introduction: Odontogenic infections are one of the common cause of maxillary sinusitis. This study aimed to evaluate the relationship between the teeth with periapical lesions or periodontal disease and sinus mucosal thickening using cone-beam computed tomography(CBCT). Methods: This was a retrospective and cross-sectional study. CBCT scans of 97 patients(188 sinuses) were evaluated retrospec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dento maxillo facial radiology

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 2008