Coiled tubing corrosion was investigated for 16 field water samples (S5 to S20) from a Canadian shale gas field. Weight loss corrosion rates of carbon steel beads incubated with these field water samples averaged 0.2 mm/yr, but injection water sample S19 had 1.25±0.07 mm/yr. S19 had a most probable number of zero acid-producing bacteria and incubation of S19 with carbon steel beads or coupons did not lead to big changes in microbial community composition. In contrast other field water samples had most probable numbers of APB of 102/mL to 107/mL and incubation of these field water samples with carbon steel beads or coupons often gave large changes in microbial community composition. HPLC analysis indicated that all field water samples had elevated concentrations of bromide (average 1.6 mM), which may be derived from bronopol, which was used as a biocide. S19 had the highest bromide concentration (4.2 mM) and was the only water sample with a high concentration of active bronopol (13.8 mM, 2760 ppm). Corrosion rates increased linearly with bronopol concentration, as determined by weight loss of carbon steel beads, for experiments with S19, with filtered S19 and with bronopol dissolved in defined medium. This indicated that the high corrosion rate found for S19 was due to its high bronopol concentration. The corrosion rate of coiled tubing coupons also increased linearly with bronopol concentration as determined by electrochemical methods. Profilometry measurements also showed formation of multiple pits on the surface of coiled tubing coupon with an average pit depth of 60 μm after 1 week of incubation with 1 mM bronopol. At the recommended dosage of 100 ppm the corrosiveness of bronopol towards carbon steel beads was modest (0.011 mm/yr). Higher concentrations, resulting if biocide is added repeatedly as commonly done in shale gas operations, are more corrosive and should be avoided. Overdosing may be avoided by assaying the presence of residual biocide by HPLC, rather than by assaying the presence of residual surviving bacteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AN INVESTIGATION ON THE PERFORMANCE OF AN IMIDAZOLINE BASED COMMERCIAL CORROSION INHIBITOR ON CO2 CORROSION OF GAS-WELL TUBING STEEL BY EIS TECHNIQUE

Abstract: The performance of an Imidazoline based commercial corrosion inhibitor in CO2 corrosion of a gas-well tubing steel was studied by employing Electrochemical Impedance Spectroscopy (EIS) technique. Inhibitor performance was investigated by means of its efficiency at various concentration and also its behavior at various exposure time. EIS results showed that inhibitor interaction to...

متن کامل

Abaqus Technology Brief

Coiled tubing is used in a variety of oil well operations including drilling, completions, and remedial activities. For each of these applications coiled tubing offers the benefits of reduced costs, speed, and reduced environmental impact. Coiled tubing possesses a limitation however, in that it may buckle in service. In this situation the tubing may be damaged, and operations may be delayed or...

متن کامل

The Effects of Boundary Conditions and Friction on the Helical Buckling of Coiled Tubing in an Inclined Wellbore

Analytical buckling models are important for down-hole operations to ensure the structural integrity of the drill string. A literature survey shows that most published analytical buckling models do not address the effects of inclination angle, boundary conditions or friction. The objective of this paper is to study the effects of boundary conditions, friction and angular inclination on the heli...

متن کامل

Control of corrosion in oil and gas production tubing

L. SMITH Controlling corrosion in production tubing is essential for maintaining production and for preventing loss of well control. Materials for use downhole have to meet criteria for corrosion resistance and also mechanical requirements. The potential corrosion rate can be estimated and the risks of sulphide stress corrosion cracking assessed on the basis of the anticipated environmental con...

متن کامل

Integration of distributed strain and temperature sensors in composite coiled tubing

Composite coiled tubing is an emerging technology in the oil & gas sector that presents important advantages compared to the steel coiled tubing and conventional drilling. The composite tube has reduced weight, allowing extended reach and improved fatigue life. An additional advantage resides in the fact that the coiled tube wall can contain and protect additional functional elements, such as e...