Urine test strips as a source of iodine contamination.
نویسندگان
چکیده
In the course of conducting an analysis in a subset of the controlled antenatal thyroid screening study (1) samples, we recently noted that some urine samples from pregnant women in Wales, a region known to be iodine deficient, had urinary iodine concentrations in excess of 500mg=L. We suspected contamination from urine test strips. We obtained Combur Test D urine test strips (Roche Diagnostics, Mannheim, Germany), as were used in the Welsh study. We also obtained Multistix 10 SG urine test strips (Bayer Health Care, Elkhart, IN), used in our clinic, for comparison. Iodine was not mentioned in the package insets for either test strip. Two urine samples were obtained from healthy volunteers. Total urinary iodine concentrations were measured both spectrophotometrically by a modification of the method of Benotti et al. (2) and by mass spectroscopy. Measurements were obtained at baseline, after placing each test strip in the urine for 1 second, and again after placing each test strip in the urine for 30 seconds (Table 1). To determine which individual tests contained iodine, the test strips were cut into separate pieces for each test, and urine iodine concentrations were remeasured after placing individual pieces in a separate urine sample for 30 seconds. Iodine was present in the tests for glucose and blood in the Combur Test D and only in the Multistix test for glucose. The test strips for glucose rely on sequential reactions. First, glucose oxidase catalyzes the aerobic oxidation of glucose to gluconic acid and hydrogen peroxide. Second, in the presence of iodide, hydrogen peroxide oxidizes the iodide to free iodine, producing a color change in the indicator. The color change produced indicates the amount of hydrogen peroxide present, and therefore the glucose content of the urine. Although previously reported by Chanoine et al. (3) over 20 years ago, the contamination of urine with iodine by test strips is not well known. Since Combur and Multistix test strips still contain iodine as a reagent for blood and glucose testing, urine iodine concentrations should be assessed before test strip measurements. This is important in evaluating populations for iodine sufficiency. References
منابع مشابه
Iodine contamination of urine samples by test strips.
2406 41 5 1 73 lodate has been recently introduced in the patches of 1395 47.6 3:41 Combur-8 Test, which involves a peroxidase (EC 1.11.1.7) 982 24.2 2.46 redox indicator system (glucose, hemoglobin) to decrease the interference ofthe reaction with ascorbic acid (4); potassium iodide is incorporated as chromogen in the glucose reagent area of N-Multistix. We hope that the report of such false-p...
متن کاملHigh willingness to use rapid fentanyl test strips among young adults who use drugs
BACKGROUND Synthetic opioid overdose mortality among young adults has risen more than 300% in the USA since 2013, primarily due to the contamination of heroin and other drugs with illicitly manufactured fentanyl. Rapid test strips, which can be used to detect the presence of fentanyl in drug samples (before use) or urine (after use), may help inform people about their exposure risk. The purpose...
متن کاملIodine and creatinine testing in urine dried on filter paper.
Iodine deficiency is a world-wide health problem. A simple, convenient, and inexpensive method to monitor urine iodine levels would have enormous benefit in determining an individual's recent iodine intake or in identifying populations at risk for iodine deficiency or excess. Current methods used to monitor iodine levels require collection of a large volume of urine and its transport to a testi...
متن کاملThe bacterial contamination rate of glucose meter test strips in the hospital setting
OBJECTIVES To assess the rate of bacterial contamination of the multi-use vial and single-use packed glucose meter strips, and to identify the type and frequency of various bacterial contamination in different hospital wards. METHODS This prospective observational study was conducted by a team from the Strategic Center for Diabetes Research in 7 general hospitals in the Central region of Saud...
متن کاملPrevalence of bacterial contamination of glucose test strips in individual single-use packets versus multiple-use vials.
BACKGROUND Glucose measurement is the cornerstone of diabetes control. In the hospital setting, the same device and package of test strips (50 or 100 strips) can be used to monitor glucose in several patients, which can increase cross contamination. The objective of our study is to measure bacterial contamination in glucose test strips, comparing results in individual single-use packets (one ho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thyroid : official journal of the American Thyroid Association
دوره 19 8 شماره
صفحات -
تاریخ انتشار 2009