Evaluation of two HbA1c point-of-care analyzers.
نویسندگان
چکیده
BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.
منابع مشابه
Correlation between Standard Clinical Chemistry and Point of Care Testing Analyzers on Hemoglobin A1C Determination
متن کامل
Trend of Changes in Blood Sugar and Glycated Hemoglobin in Electronic Health Records, Sari, Iran 2012- 2018
Background and purpose: High prevalence of Type 2 Diabetes Mellitus (T2DM) and its demand for regular care have resulted in a massive amount of electronic health records (EHRs). Hemoglobin A1c (HbA1c) and Fasting Blood Sugar (FBS) levels are two widely-used diagnostic measures for evaluation of diabetes care. This study aimed at assessing Family Medicine Plan (FMP) and exploring the trend of ch...
متن کاملEvaluation of the effect of using Symptom Focused Management Model (SFMM) on the amount of HbA1c, knowledge, and self care behavior of type 2 diabetes patients
Background: Diabetes control needs more effective educational programs. Self-care education is an important factor in diabetes control. It seems that the symptoms can be the proper stimulus for the direction toward self-care. Aim: To evaluate the effects of the using SFMM on HbA1c, knowledge, self care practices, and symptoms of type2 diabetic patients. Methods: Seventy type 2 diabetic patients...
متن کاملAnalysis of office-based glycohemoglobin measurement.
Hemoglobin A1c (HbA1c) measurements are important for monitoring glycemic control in patients with diabetes. The positive impact of point-of-care HbA1c measurements on patient management is described in the literature. The general analytical requirements for HbA1c testing are described. The analytical evaluation of a new point-of-care HbA1c analyzer, suitable for a physician's office, against t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 49 4 شماره
صفحات -
تاریخ انتشار 2011