Rapid SPECT simulation of downscatter in non-uniform media.

نویسندگان

  • H W de Jong
  • F J Beekman
چکیده

A rotation-based Monte Carlo (MC) simulation method (RMC) has been developed, designed for rapid calculation of downscatter through non-uniform media in SPECT. A possible application is downscatter correction in dual isotope SPECT. With RMC, only a fraction of all projections of a SPECT study have to be MC simulated in a standard manner. The other projections can be estimated rapidly using the results of these standard MC calculations. For efficiency, approximations have to be made in RMC with regard to the final scatter angle of the detected photons. Further speed-up is obtained by combining RMC with convolution-based forced detection (CFD) instead of forced detection (FD), which is a more common variance reduction technique for MC. The RMC method was compared with standard MC for 99mTc downscatter in a 201Tl window (72 keV+/-10%) using a digital thorax phantom. The resulting scatter projections are in good agreement (maximum bias a few per cent of the largest value in the projection), but RMC with CFD is about three orders in magnitude faster than standard MC with FD and up to 25 times faster than standard MC with CFD. Using RMC combined with CFD, the generation of 64 almost noise-free downscatter projections (64 x 64) takes only a couple of minutes on a 500 MHz Pentium processor. Therefore, rotation-based Monte Carlo could serve as a practical tool for downscatter correction schemes in dual isotope SPECT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Planar and SPECT Monte Carlo acceleration using a variance reduction technique in I131 imaging

Background: Various variance reduction techniques such as forced detection (FD) have been implemented in Monte Carlo (MC) simulation of nuclear medicine in an effort to decrease the simulation time while keeping accuracy. However most of these techniques still result in very long MC simulation times for being implemented into routine use. Materials and Methods: Convolution-based force...

متن کامل

A new approach to scatter correction in SPECT images based on Klein_Nishina equation

Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. Methods: The objective of this paper is to develop and validate a scatter correction technique ...

متن کامل

Attenuation Correction in SPECT during Image Reconstruction using an Inverse Monte Carlo Method: A Simulation Study

Introduction: The main goal of SPECT imaging is to determine activity distribution inside the organs of the body. However, due to photon attenuation, it is almost impossible to do a quantitative study. In this paper, we suggest a mathematical relationship between activity distribution and its corresponding projections using a transfer matrix. Monte Carlo simulation was used to find a precise tr...

متن کامل

Transport Property Estimation of Non-Uniform Porous Media

In this work a glass micromodel which its grains and pores are non-uniform in size, shape and distribution is considered as porous medium. A two-dimensional random network model of micromodel with non-uniform pores has been constructed. The non-uniformity of porous model is achieved by assigning parametric distribution functions to pores throat and pores length, which was measured using ima...

متن کامل

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 46 3  شماره 

صفحات  -

تاریخ انتشار 2001