A Non-invasive Real-Time Method for Measuring Variable Stiffness

نویسندگان

  • Giorgio Grioli
  • Antonio Bicchi
چکیده

The need for adaptability to the environment, energy conservation, and safety during physical interaction with humans of many advanced robotic applications has prompted the development of a number of Variable Stiffness Actuators (VSA). These have been implemented in a variety of ways, using different transduction technologies (electromechanical, pneumatic, hydraulic, but also piezoelectric, active polymeric, etc. ) and arrangements with elastic elements. All designs share a fundamentally unavoidable nonlinear behavior. The control schemes proposed for these actuators typically aim at independently controlling the position (or force) of the link, and its stiffness with respect to external disturbances. Although effective feedback control schemes using position and force sensors are commonplace in robotics, control of stiffness is at present completely open–loop. In practice, instead of measuring stiffness, it is inferred from the mathematical model of the actuator. Being this in most cases only roughly known, model mismatches affect severely stiffness control, undermining its utility. It should be noticed that, while for constant stiffness elements an accurate calibration of the model is possible, the same approach is hardly viable for variable stiffness systems. We propose a method for estimating stiffness while it is varied, either intentionally or not, hence without knowledge of the command inputs. The method uses instantaneous measurements of force and position at one of the ends of the compliant elements in the system, and derives a measure that asymptotically converges to the current value of stiffness, up to an error which can be bounded by an arbitrarily small value. Simulation and experimental results are provided, which illustrate the performance of the proposed measurement method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Bio Signal Processing System for Pulse Wave Velocity Detection

Pulse wave velocity (PWV) is the most popular index to assessment the arterial stiffness. Currently, several non-invasive examination methods with single channel for PWV are announced. This paper proposes a non-invasive digital volume pulse (DVP) measuring system using a dual channel simultaneous measurement method try to meet the demands for home healthcare equipment which is easy to operate. ...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Reliability of Body Landmarks Analyzer for Measuring the Quadriceps Angle

Genovarum and Genovalgum are the most common postural deformities of the knee joint. A quadriceps angle is used to measure these anomalies. Methods of measuring this angle are divided into two categories: invasive and non-invasive. The purpose of the present research was to study the inter/intra rater reliability of the non-invasive Body Landmarks Analyzer method for measuring of the quadriceps...

متن کامل

Quantification and Optimization of Candida albicans DNA in Blood Samples Using Real- Time PCR

Background: Candida albicans (C. albicans) is a major cause of candidaemia in people with impaired immunity. Blood culture is a “gold standard” for candidaemia detection but is time-consuming and relatively insensitive. We established a real-time PCR assay for C. albicans detection in blood by LightCycler PCR and melting curve analysis. Methods: Five milliliter blood samples from...

متن کامل

O-45: Quantification of Cell-Free-Fetal-DNAfrom Maternal Plasma for the First Time in Pakistan:Implications for Non-Invasive PrenatalDiagnosis of Genetic Disorders

Background: Current prenatal diagnosis requires invasive testing which carries a 1-4% procedure-related-risk of miscarriage; hence, non-invasive techniques are desired. The recent demonstration of cell-free-fetal-DNA enriched from maternal plasma has opened new possibilities for non-invasive-prenatal-diagnosis of not only genetic-disorders such as β-thalassaemia and haemophilia but also chromos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010