Functional and structural response of arterialized femoral veins in a rodent AV fistula model.

نویسندگان

  • Stephan Langer
  • Christian Heiss
  • Niklas Paulus
  • Nuran Bektas
  • Gottfried Mommertz
  • Zuzanna Rowinska
  • Ralf Westenfeld
  • Michael J Jacobs
  • Michael Fries
  • Thomas A Koeppel
چکیده

BACKGROUND Neointimal hyperplasia is considered to be the major cause of arteriovenous fistula (AVF) failure, resulting in vein wall thickening, stenosis and, ultimately, occlusion. Ultrasound (US) has been shown to be effective for detecting these morphological changes in patients. The aim of this study was to develop an experimental AVF model in the rat that shows typical features of fistula maturation and allows longitudinal monitoring of fistula veins by high-resolution ultrasound. METHODS AVFs were created by a handsewn end-to-side anastomosis between the femoral vein and the femoral artery in 15 rats. A group of sham-operated animals (n = 3) served as controls. Time-related functional and morphological AVF characteristics were assessed up to 12 weeks using ultrasound (15-MHz transducer) and were correlated to histopathological changes. RESULTS All rats survived surgery, and the patency rate was 93%. US showed a 2-fold increase in the fistula vein diameter and mean flow velocity as well as a 4-fold increase in the intima-media thickness without significant luminal loss. The afferent femoral artery exhibited no change in intima-media thickness and only minimal adaptive increases in diameter and flow velocity. Histological evaluation confirmed these observations. CONCLUSIONS Our AVF model in the rat demonstrates maturation effects in fistula veins similar to typical clinical findings in haemodialysis patients. Noninvasive ultrasound proved to be a valuable tool for longitudinal in vivo monitoring of the fistulas in this rodent model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی کارایی فیستول شریانی وریدی صافنوفمورال جهت همودیالیز در بیماران مبتلا به نارسا یی مزمن کلیه

Introduction: To describe the outcome of the sapheno-femoral fistula as an alternative blood access site for maintenance hemodialysis in a prospective cohort of patients with end - stage renal failure. Methods: Twenty-two patients with vascular access failure in the arms were admitted for establishing sapheno-femoral fistula as a puncture site for hemodialysis. The major saphenous vein was exp...

متن کامل

Endovascular repair of posttraumatic multiple femoral-femoral and popliteal-popliteal arteriovenous fistula with Viabahn and excluder stent graft Eendovaskularno zbrinjavanje posttraumatske multiple femoralnofemoralne i poplitealnopoplitealne arteriovenske fistule primenom Viabahn i ekskluder stent grafta

Background. Traumatic arteriovenous (AV) fistula is considered to be a pathologic communication between the arterial and venous systems following injury caused mostly by firearms, sharp objects or blasting agents. Almost 50% of all traumatic AV fistulas are localized in the extremities. In making diagnosis, besides injury anamnesis data, clinical image is dominated by palpable thrill and auscul...

متن کامل

Small skin incision and fistula elevation for hemodialysis using the femoral vein.

BACKGROUND Wound morbidity commonly accompanies transposition of the femoral vein when used for hemodialysis access, mainly because of the length of the skin incision. A short incision may reduce wound complications but may compromise the arteriovenous (AV) function because of the shorter length of femoral vein available for puncture. This report presents our experience with a modification of t...

متن کامل

Venous stenosis in a pig arteriovenous fistula model--anatomy, mechanisms and cellular phenotypes.

BACKGROUND Haemodialysis vascular access dysfunction is currently a huge clinical problem. Although arteriovenous (AV) fistulae are the preferred mode of dialysis access, they have significant problems with both early (failure to mature) and late fistula failure. Both are characterized radiologically as a stenosis of the venous segment. Despite the magnitude of the clinical problem, the exact p...

متن کامل

پیش‌بینی شکست زودرس فیستولهای شریانی- وریدی بر مبنای معاینه در خاتمه جراحی

Background: For patients requiring chronic hemodialysis, the preferred site for vascular access is an autogenous arteriovenous fistula. Although a properly formed fistula is advantageous because it is less susceptible than other types of vascular accesses to infection and clot formation and can last longer than any other types of vascular access, AV fistula has a high rate of early failure that...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 24 7  شماره 

صفحات  -

تاریخ انتشار 2009