Treatment of Escherichia coli O157:H7 inoculated alfalfa seeds and sprouts with electrolyzed oxidizing water.

نویسندگان

  • Ratna R Sharma
  • Ali Demirci
چکیده

Electrolyzed oxidizing water is a relatively new concept that has been utilized in agriculture, livestock management, medical sterilization, and food sanitation. Electrolyzed oxidizing (EO) water generated by passing sodium chloride solution through an EO water generator was used to treat alfalfa seeds and sprouts inoculated with a five-strain cocktail of nalidixic acid resistant Escherichia coli O157:H7. EO water had a pH of 2.6, an oxidation-reduction potential of 1150 mV and about 50 ppm free chlorine. The percentage reduction in bacterial load was determined for reaction times of 2, 4, 8, 16, 32, and 64 min. Mechanical agitation was done while treating the seeds at different time intervals to increase the effectiveness of the treatment. Since E. coli O157:H7 was released due to soaking during treatment, the initial counts on seeds and sprouts were determined by soaking the contaminated seeds/sprouts in 0.1% peptone water for a period equivalent to treatment time. The samples were then pummeled in 0.1% peptone water and spread plated on tryptic soy agar with 5 microg/ml of nalidixic acid (TSAN). Results showed that there were reductions between 38.2% and 97.1% (0.22-1.56 log(10) CFU/g) in the bacterial load of treated seeds. The reductions for sprouts were between 91.1% and 99.8% (1.05-2.72 log(10) CFU/g). An increase in treatment time increased the percentage reduction of E. coli O157:H7. However, germination of the treated seeds reduced from 92% to 49% as amperage to make EO water and soaking time increased. EO water did not cause any visible damage to the sprouts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inactivation of Escherichia Coli O157:h7 on Inoculated Alfalfa Seeds during Exposure to Ozonated or Electrolyzed Oxidizing Water

Alfalfa sprouts contaminated with Escherichia coli O157:H7 and Salmonella have been implicated in a number of foodborne disease outbreaks in recent years. Seeds are attributed to be the main source of contamination for sprouts. Data from studies on the treatment of E. coli O157:H7 inoculated alfalfa seeds with ozonated and electrolyzed oxidizing (EO) water were used to develop models for predic...

متن کامل

Effects of Ultrasound, Irradiation, and Acidic Electrolyzed Water on Germination of Alfalfa and Broccoli Seeds and Escherichia coli O157:H7

The ability of power ultrasound, acidic electrolyzed water (AEW), and gamma irradiation to inactivate Escherichia coli O157:H7 inoculated onto alfalfa and broccoli seeds was examined. The treatment conditions under which the alfalfa and broccoli seeds treated with sterile deionized water (SW), AEW, ultrasound cleaning tank (UST), ultrasound probe (USP), and irradiation (IR) would retain a germi...

متن کامل

Evaluation of various antimicrobial interventions for the reduction of Escherichia coli O157:H7 on bovine heads during processing.

The effectiveness of electrolyzed oxidizing water, FreshFx, hot water, DL-lactic acid, and ozonated water was determined using a model carcass spray-washing cabinet. A total of 140 beef heads obtained from a commercial processing line were inoculated with Escherichia coli O157:H7 on the cheek areas. Each head was exposed to a simulated preevisceration wash and then had antimicrobial wash treatm...

متن کامل

Effectiveness of electrolyzed acidic water in killing Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes on the surfaces of tomatoes.

A study was conducted to evaluate the efficacy of electrolyzed acidic water, 200-ppm chlorine water, and sterile distilled water in killing Escherichia coli O157:H7, Salmonella, and Listeria monocytogenes on the surfaces of spot-inoculated tomatoes. Inoculated tomatoes were sprayed with electrolyzed acidic water, 200-ppm chlorine water, and sterile distilled water (control) and rubbed by hand f...

متن کامل

Efficacy of electrolyzed oxidizing water for inactivating Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes.

The efficacy of electrolyzed oxidizing water for inactivating Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes was evaluated. A five-strain mixture of E. coli O157:H7, S. enteritidis, or L. monocytogenes of approximately 10(8) CFU/ml was inoculated in 9 ml of electrolyzed oxidizing water (treatment) or 9 ml of sterile, deionized water (control) and incubated at 4 or ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of food microbiology

دوره 86 3  شماره 

صفحات  -

تاریخ انتشار 2003