Flow reversal at low voltage and low frequency in a microfabricated ac electrokinetic pump.

نویسندگان

  • Misha Marie Gregersen
  • Laurits Højgaard Olesen
  • Anders Brask
  • Mikkel Fougt Hansen
  • Henrik Bruus
چکیده

Microfluidic chips have been fabricated in Pyrex glass to study electrokinetic pumping generated by a low-voltage ac bias applied to an in-channel asymmetric metallic electrode array. A measurement procedure has been established and followed carefully resulting in a high degree of reproducibility of the measurements over several days. A large coverage fraction of the electrode array in the microfluidic channels has led to an increased sensitivity allowing for pumping measurements at low bias voltages. Depending on the ionic concentration a hitherto unobserved reversal of the pumping direction has been measured in a regime, where both the applied voltage and the frequency are low, V(rms)<1.5 V and f<20 kHz , compared to previously investigated parameter ranges. The impedance spectrum has been thoroughly measured and analyzed in terms of an equivalent circuit diagram to rule out trivial circuit explanations of our findings. Our observations agree qualitatively, but not quantitatively, with theoretical electrokinetic models published in the literature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexible Power Electronic Transformer for Power Flow Control Applications

This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...

متن کامل

The effect of step height on the performance of three-dimensional ac electro-osmotic microfluidic pumps.

Recent numerical and experimental studies have investigated the increase in efficiency of microfluidic ac electro-osmotic pumps by introducing nonplanar geometries with raised steps on the electrodes. In this study, we analyze the effect of the step height on ac electro-osmotic pump performance. AC electro-osmotic pumps with three-dimensional electroplated steps are fabricated on glass substrat...

متن کامل

A new control strategy for SSSC to improve low-frequency oscillations damping

When power systems are expanded and connected together with weak tie lines, the low-frequency oscillations are increased and the stability margin of the power system decreases. Therefore, when designing the transmission system to be used, it is necessary to maintain the dynamic stability of the power system, and to make sure to have the most possible stability margin. SSSC is a FACTS device con...

متن کامل

A new control strategy for SSSC to improve low-frequency oscillations damping

When power systems are expanded and connected together with weak tie lines, the low-frequency oscillations are increased and the stability margin of the power system decreases. Therefore, when designing the transmission system to be used, it is necessary to maintain the dynamic stability of the power system, and to make sure to have the most possible stability margin. SSSC is a FACTS device con...

متن کامل

ac electrokinetic micropumps: the effect of geometrical confinement, Faradaic current injection, and nonlinear surface capacitance.

Recent experiments have demonstrated that ac electrokinetic micropumps permit integrable, local, and fast pumping (velocities approximately mm/s) with low driving voltage of a few volts only. However, they also displayed many quantitative and qualitative discrepancies with existing theories. We therefore extend the latter theories to account for three experimentally relevant effects: (i) vertic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review. E, Statistical, nonlinear, and soft matter physics

دوره 76 5 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2007