Comparison of orthodox with fibreoptic orotracheal intubation under total i.v. anaesthesia.

نویسندگان

  • H G Schaefer
  • S C Marsch
چکیده

Fibreoptic orotracheal intubation was compared with orthodox laryngoscopy and tracheal intubation using a total i.v. technique with propofol in 60 ASA I and II patients. There was no significant difference between the two techniques in haemodynamic profile (before, during and following the intubation procedure) and incidence of postoperative sore throat. Minimal oxygen saturation was 96% during the study; maximal end-tidal PCO2 after intubation was 5.4 kPa. Intubation time was faster (P less than 0.01) in the orthodox group (30.7 (SEM 2.3) s) than in the fibreoptic group (52.7 (4.8) s).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients.

Sixty patients with no clinical indicators of a difficult airway were selected to undergo a fibreoptic assessment after induction of general anaesthesia using both the Berman Intubating Airway and the Williams Airway Intubator. The bronchoscopic view and ease of railroading a tracheal tube during fibreoptic orotracheal intubation were studied. The bronchoscopic views obtained by the Berman Airw...

متن کامل

Blood pressure and heart rate changes during fibreoptic orotracheal intubation: a comparison of children and adults.

BACKGROUND AND OBJECTIVES Autonomic circulatory regulation and airway anatomy in children are significantly different from those in adults. There is no available published data to compare whether there is a clinically relevant difference in the haemodynamic responses to fibreoptic orotracheal intubation (FOI) under the same conditions between children and adults. In this randomized clinical stu...

متن کامل

Randomized, controlled trial of the double setup tracheal tube during fibreoptic orotracheal intubation under general anaesthesia.

BACKGROUND Impingement of the tracheal tube (ETT) on upper airway structures during railroading over the fibreoptic bronchoscope (FOB) occurs commonly. Potential complications of impingement include prolonged intubation time, leading to arterial desaturation, failed intubation and laryngeal trauma. The objective of this randomized, controlled trial was to assess the effect of the double setup E...

متن کامل

Comparison of two methods of fibrescope-guided tracheal intubation.

We have compared intubation time and cardiovascular effects of fibrescope-guided orotracheal intubation aided by the Berman 11 Intubating Airway with those of the tongue traction method of fibreoptic intubation and with conventional Macintosh intubation. We studied 75 patients who received a standard general anaesthetic which included non-depolarizing neuromuscular block; they were allocated ra...

متن کامل

Fibreoptic awake intubation--a method of topical anaesthesia and orotracheal intubation.

Three cases of trismus caused by oropharyngeal sepsis are described where fibreoptic-assisted awake intubation using an oral airway intubator and nebulised lidocaine was safely and successfully achieved.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 66 5  شماره 

صفحات  -

تاریخ انتشار 1991