The effect of the angle of suture anchor insertion on fixation failure at the tendon-suture interface after rotator cuff repair: deadman's angle revisited.
نویسندگان
چکیده
PURPOSE To evaluate what effect the angle of screw-in suture anchor insertion has on fixation stability at the suture-tendon interface. METHODS Supraspinatus tendons from 7 matched pairs of human cadaveric shoulders were split, yielding 4 tendons per cadaver. An experimental rotator cuff tear was created and repaired, using a 5.0-mm diameter screw-in suture anchor. In a staggered, matched pair arrangement, the angle of anchor insertion was varied between 45 degrees (deadman's angle) and 90 degrees to the articular surface. Each repair underwent cyclic loading, and 2 failure points were defined: the first at 3 mm of repair site gap formation and the second at the point of complete failure. The number of cycles to failure was compared between the 2 groups. RESULTS The mean number of cycles to 3-mm gap formation for anchors inserted at 90 degrees was 380. This was significantly higher than for repairs made with the 45 degrees angle of anchor insertion (mean, 297 cycles). Complete failure occurred at a significantly greater number of cycles with the 90 degrees anchors (mean, 443 cycles) compared with the 45 degrees anchors (mean, 334 cycles). CONCLUSIONS Compared with anchors placed at the current standard of the deadman's angle of 45 degrees, suture anchors placed at 90 degrees to the junction of the greater tuberosity and the humeral head articular surface provided improved soft tissue fixation in an experimental rotator cuff model. CLINICAL RELEVANCE The angle of suture anchor insertion into the greater tuberosity during rotator cuff repair has an effect on the soft tissue fixation at the tendon-suture interface.
منابع مشابه
Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques.
BACKGROUND Although many studies involving rotator cuff repair fixation have focused on ultimate fixation strength and ability to restore the tendon's native footprint, no studies have characterized the stability of the repair with regard to motion between the tendon and repair site footprint. HYPOTHESIS Suture anchor fixation for rotator cuff repair has greater interface motion between tendo...
متن کاملFrontal Plane Humeral Elevation Effects on the Pullout Strength of Suture Anchors Used in Rotator Cuff Repair
Frontal plane humeral elevation effects on the pullout strength of suture anchors used in rotator cuff repair The rotator cuff offers the stabilizing forces necessary for fine arm movement. The most common injury to the rotator cuff is the partial or full thickness tear of the supraspinatus tendon, which attaches the humerus to the scapula on the superior side, due to an acute or chronic injury...
متن کاملArthroscopic single-row versus double-row suture anchor rotator cuff repair.
BACKGROUND Recurrent defects after open and arthroscopic rotator cuff repair are common. Double-row repair techniques may improve initial fixation and quality of rotator cuff repair. PURPOSE To evaluate the load to failure, cyclic displacement, and anatomical footprint of 4 arthroscopic rotator cuff repair techniques. HYPOTHESIS Double-row suture anchor repair would have superior structural...
متن کاملComparison of the Fixation Strength of PEEK Knotless Suture Anchors for Rotator Cuff Repair
INTRODUCTION Rotator cuff injuries are common, with approximately 400,000 cuff repairs performed each year in the United States alone. Surgical repair of torn cuff tendons involves reattachment of the torn end of the tendon to the original footprint on the proximal humerus, typically using suture anchors. In recent years, suture anchors have evolved into knotless systems, which are designed to ...
متن کاملCyclic loading of anchor-based rotator cuff repairs: confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation.
Previous experimental studies of failure of rotator cuff repair have involved single pull to ultimate load. Such an experimental design does not represent the cyclic loading conditions experienced in vivo. We created 1 x 2 cm rotator cuff defects in 16 cadaver shoulders, repaired each defect with three Mitek-RC suture anchors (Mitek Surgical Products, Inc, Westwood, MA) using simple sutures of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
دوره 25 6 شماره
صفحات -
تاریخ انتشار 2009