Understanding Changes in Tumor Texture Indices in PET: A Comparison Between Visual Assessment and Index Values in Simulated and Patient Data.

نویسندگان

  • Fanny Orlhac
  • Christophe Nioche
  • Michaël Soussan
  • Irène Buvat
چکیده

The use of texture indices to characterize tumor heterogeneity from PET images is being increasingly investigated in retrospective studies, yet the interpretation of PET-derived texture index values has not been thoroughly reported. Furthermore, the calculation of texture indices lacks a standardized methodology, making it difficult to compare published results. To allow for texture index value interpretation, we investigated the changes in value of 6 texture indices computed from simulated and real patient data. Methods: Ten sphere models mimicking different activity distribution patterns and the 18F-FDG PET images from 54 patients with breast cancer were used. For each volume of interest, 6 texture indices were measured. The values of texture indices and how they changed as a function of the activity distribution were assessed and compared with the visual assessment of tumor heterogeneity. Results: Using the sphere models and real tumors, we identified 2 sets of texture indices reflecting different types of uptake heterogeneity. Set 1 included homogeneity, entropy, short-run emphasis, and long-run emphasis, all of which were sensitive to the presence of uptake heterogeneity but did not distinguish between hyper- and hyposignal within an otherwise uniform activity distribution. Set 2 comprised high-gray-level-zone emphasis and low-gray-level-zone emphasis, which were mostly sensitive to the average uptake rather than to the uptake local heterogeneity. Four of 6 texture indices significantly differed between homogeneous and heterogeneous lesions as defined by 2 nuclear medicine physicians (P < 0.05). All texture index values were sensitive to voxel size (variations up to 85.8% for the most homogeneous sphere models) and edge effects (variations up to 29.1%). Conclusion: Unlike a previous report, our study found that variations in texture indices were intuitive in the sphere models and real tumors: the most homogeneous uptake distribution exhibited the highest homogeneity and lowest entropy. Two families of texture index reflecting different types of uptake patterns were identified. Variability in texture index values as a function of voxel size and inclusion of tumor edges was demonstrated, calling for a standardized calculation methodology. This study provides guidance for nuclear medicine physicians in interpreting texture indices in future studies and clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SNMMI Leadership Update: Preparing the Next Generation of Nuclear Medicine Professionals.

379 Safety, Dosimetry, and Tumor Detection Ability of Ga-NOTA-AE105: First-in-Human Study of a Novel Radioligand for uPAR PET Imaging Dorthe Skovgaard, Morten Persson, Malene Brandt-Larsen, Camilla Christensen, Jacob Madsen, Thomas Levin Klausen, Søren Holm, Flemming Littrup Andersen, Annika Loft, Anne Kiil Berthelsen, Helle Pappot, Klaus Brasso, Niels Kroman, Liselotte Højgaard, and Andreas Kj...

متن کامل

Comparison of PET/CT and CT-based tumor delineation and its effects on the radiation treatment planning for non-small cell lung cancer

Introduction: Tumor volume delineation is the most important step in the radiation treatment planning. In this study the impact of PET/CT data on the tumor delineation precision of non-small cell lung cancer (NSCLC) was investigated. Methods: PET/CT images of 20 patients with primary NSCLC were obtained and imported to the treatment planning system for im...

متن کامل

Use of Becker and neurotic pressure bioclimatic indices in the Assessment of Thermal Comfort in Outdoor Environments based on Meteorological Data: Case Study in Three Different Climates of Iran

Background and aims: lack of thermal comfort in outdoor environments, can cause disorders and diseases, negative impact on productivity and performance, and even can cause death. Therefore, it is important to evaluate it. Various indices and models have been used to assess the level of comfort of humans. In most evaluations has been tried to estimate the comfort level using meteorological data ...

متن کامل

Assessment of the Wavelet Transform for Noise Reduction in Simulated PET Images

Introduction: An efficient method of tomographic imaging in nuclear medicine is positron emission tomography (PET). Compared to SPECT, PET has the advantages of higher levels of sensitivity, spatial resolution and more accurate quantification. However, high noise levels in the image limit its diagnostic utility. Noise removal in nuclear medicine is traditionally based on Fourier decomposition o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 58 3  شماره 

صفحات  -

تاریخ انتشار 2017