Incidental pathologic extracardiac uptake of 99mTc-tetrofosmin in myocardial perfusion imaging.

نویسندگان

  • Irini Kotsalou
  • Panagiotis Georgoulias
  • Stefanos Fourlis
  • Antonis Zoumboulidis
  • Konstantinos Giaslakiotis
  • Athina Androulaki
  • Panagiotis Chronopoulos
  • Nikolaos Dimakopoulos
چکیده

Technetium-99m-tetrofosmin ((99m)Tc-TF) myocardial perfusion studies have incidentally detected various extracardiac abnormalities. The interpretation of these findings may be essential for early diagnosis and treatment of important diseases. We present a rare case of a mediastinal thymoma incidently detected during myocardial perfusion imaging. A 60 year-old woman, with precardiac symptoms of possible myocardial ischemia, underwent a (99m)Tc-TF stress-rest single photon emission tomography test. Intense uptake of the radiotracer in the left paracardiac area, was observed. The computerized tomography and the magnetic resonance imaging tests revealed a mass in the left lower anterior mediastinal area. Biopsy and subsequent histology showed that this mass was a thymoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidental pathologic extracardiac uptake of (99m)Tc-tetrofosmin in myocardial perfusion imaging: Importance of patient background evaluation.

(99m)Tc-tetrofosmin single photon emission computed tomography ((99m)Tc-tetrofosmin SPECT) has an important role in the assessment of coronary artery disease. Despite being its main indication, this study does not only evaluate myocardial perfusion, but much more. Moreover, during the SPECT acquisition, the field area covered includes many important organs of the thorax and abdomen, so extracar...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease.

UNLABELLED This study was designed to compare the tracer kinetics between 99mTc-sestamibi and 99mTc-tetrofosmin in a heterogeneous group of 24 patients admitted for routine perfusion imaging. METHODS Twelve patients were studied with 99mTc-tetrofosmin and 12 with 99mTc-sestamibi. In each group, six patients had a low likelihood for coronary artery disease, and six patients had angiographicall...

متن کامل

Myocardial uptake characteristics of three 99mTc-labeled tracers for myocardial perfusion imaging one hour after rest injection.

OBJECTIVE 99mTc-tetrofosmin and 99mTc-sestamibi are approved tracers for myocardial perfusion studies. Recently, a 99mTc-MIBI preparation from a different manufacturer (99mTc-cardiospect-MIBI) has been introduced to the market. Therefore, the aim of this study was the evaluation of 99mTc-tetrofosmin as well as of two different 99mTc-labeled MIBI tracers with regard to differences in imaging qua...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hellenic journal of nuclear medicine

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2008