Temperature effects and accuracy of MOS radiation dosimeters

نویسندگان

  • G. SARRABAYROUSE
  • S. SISKOS
چکیده

-The influence of the irradiation dose on the parameters which control the temperature sensitivity of thick oxide p-MOS ionising radiation dosimeters is investigated. The temperature sensitivity of the threshold voltage, the carrier mobility and the minimum temperature coefficient current appear to be dose-dependent contrary to what is generally considered. The consequences on the dose measurement accuracy of the dosimeter is discussed with respect to the measurement procedure. Key-Words : MOS radiation dosimeter, ionising radiation, temperature effects, accuracy

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical properties of MOS radiation dosimeters

2014 MOS transistors are used for radiation dosimetry. The sensitivity obtained is ranging between 20 mV/ Gray (SiO2) and 1,5 V/Gray (SiO2). Good linearity and stability of the transistor response is obtained. Revue Phys. Appl. 21 (1986) 283-287 AVRIL 1986, Classification Physics Abstracts 73. 60D

متن کامل

Diffusion measurement in ferrous infused gel dosimeters

Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe2+ ion to Fe3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours af...

متن کامل

Dosimetry characterization of nitro-blue tetrazolium polyvinyl butyral films for radiation processing

Nitro-blue tetrazolium polyvinyl butyral film dosimeters (NBT-PVB) were prepared and investigated based on radiation-induced reduction of NBT. NBT-PVB film dosimeters containing different concentrations of NBT dye from 1 to 5 mM were prepared in a solution of ethanol. The dosimeters were irradiated with g-ray from Co source at doses from 5 up to 55 kGy. UV/vis spectrophotometry was used to inve...

متن کامل

Three dimensional radiation dosimetry using polymer gels

The use of polymer gels to record radiation dose distributions in three dimensions was first proposed in 1992 as a proof-of-principle [1]. The accuracy of these early polymer gel dosimeters and scanning methods was not sufficient for most clinical applications [2]. Since then, several efforts were made to increase the accuracy and precision of both the physical gel dosimeter and the scanning te...

متن کامل

A Validation Study on Radiation properties of a Novel LiF: Mg, Ti Known as IAP-100

Introduction: LiF dosimeter has the most application in medicine. This study aimed to evaluate some dosimetric properties of a novel LiF: Mg, Ti. Materials and Methods: An ELEKTA Precise linear accelerator was used to calibrate dosimeters at 6 MV. In this survey, responses of dosimeters were evaluated up to 1000 cGy. Background effect was investigated in two different dosimeter states includin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008