Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense.

نویسندگان

  • Paul E Marik
  • Rodrigo Cavallazzi
چکیده

BACKGROUND Despite a previous meta-analysis that concluded that central venous pressure should not be used to make clinical decisions regarding fluid management, central venous pressure continues to be recommended for this purpose. AIM To perform an updated meta-analysis incorporating recent studies that investigated indices predictive of fluid responsiveness. A priori subgroup analysis was planned according to the location where the study was performed (ICU or operating room). DATA SOURCES MEDLINE, EMBASE, Cochrane Register of Controlled Trials, and citation review of relevant primary and review articles. STUDY SELECTION Clinical trials that reported the correlation coefficient or area under the receiver operating characteristic curve (AUC) between the central venous pressure and change in cardiac performance following an intervention that altered cardiac preload. From 191 articles screened, 43 studies met our inclusion criteria and were included for data extraction. The studies included human adult subjects, and included healthy controls (n = 1) and ICU (n = 22) and operating room (n = 20) patients. DATA EXTRACTION Data were abstracted on study characteristics, patient population, baseline central venous pressure, the correlation coefficient, and/or the AUC between central venous pressure and change in stroke volume index/cardiac index and the percentage of fluid responders. Meta-analytic techniques were used to summarize the data. DATA SYNTHESIS Overall 57% ± 13% of patients were fluid responders. The summary AUC was 0.56 (95% CI, 0.54-0.58) with no heterogenicity between studies. The summary AUC was 0.56 (95% CI, 0.52-0.60) for those studies done in the ICU and 0.56 (95% CI, 0.54-0.58) for those done in the operating room. The summary correlation coefficient between the baseline central venous pressure and change in stroke volume index/cardiac index was 0.18 (95% CI, 0.1-0.25), being 0.28 (95% CI, 0.16-0.40) in the ICU patients, and 0.11 (95% CI, 0.02-0.21) in the operating room patients. CONCLUSIONS There are no data to support the widespread practice of using central venous pressure to guide fluid therapy. This approach to fluid resuscitation should be abandoned.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Different levels of ventilation are a plausible explanation for different outcomes of acute stroke patients undergoing endovascular therapy.

1. Practice advisory for perioperative visual loss associated with spine surgery: An updated report by the American Society of Anesthesiologists Task Force on Perioperative Visual Loss. ANESTHESIOLOGY 2012; 116:274 – 85 2. Marik PE, Baram M, Vahid B: Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008; 134:172–...

متن کامل

Assessing Volume Status and Fluid Responsiveness in Resuscitation

Marik PE, Baram M, Vahid B: Does the central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008, 134:172-178. Central venous pressure measurements are utilized in many intensive care units (ICUs), emergency departments, and operating rooms throughout the world. It is used to assess the fluid status of patients and to aid i...

متن کامل

Dynamic and Volumetric Variables Reliably Predict Fluid Responsiveness in a Porcine Model with Pleural Effusion

BACKGROUND The ability of stroke volume variation (SVV), pulse pressure variation (PPV) and global end-diastolic volume (GEDV) for prediction of fluid responsiveness in presence of pleural effusion is unknown. The aim of the present study was to challenge the ability of SVV, PPV and GEDV to predict fluid responsiveness in a porcine model with pleural effusions. METHODS Pigs were studied at ba...

متن کامل

Stroke volume variation and pleth variability index to predict fluid responsiveness during resection of primary retroperitoneal tumors in Hans Chinese.

Respiration variation in arterial pulse pressure (ΔPP) and pulse oximetry plethysmographic waveform amplitude (ΔPOP) are accurate predictors of fluid responsiveness in mechanically ventilated patients. We hypothesized that stroke volume variation (SVV) and pleth variability index (PVI) can predict fluid responsiveness in mechanically ventilated patients during major surgical procedures in H...

متن کامل

بررسی ارزش تشخیصی میزانCaval index در تعیین فشار ورید مرکزی پایین در مقایسه با روش تهاجمی در بیماران بستری در ICU بیمارستان شهید باهنر کرمان

Introduction: Measurement of central venous pressure can be regarded as a beneficial guide in order to assess a patient's hemodynamic status, specifically in patient with sever sepsis and septic shock, for whom a central venous pressure of less than 8mmhg is considered as an indicator for aggressive intravenous fluid replacement. Therefore, this study aimed to investigate the ultrasonographic e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 41 7  شماره 

صفحات  -

تاریخ انتشار 2013