PFC / JA - 93 - 25 ITER Millimeter - Wave CTS Diagnostic Option

نویسندگان

  • P. P. Woskov
  • D. R. Cohn
چکیده

Localized alpha-particle velocity distribution and density, ion temperature, DT fuel ratio, and internal magnetic field pitch angle can all be potentially diagnosed by a collective Thomson scattering system. Relativistic electron cyclotron calculations and TORAY ray tracing for 6 tesla ITER parameters indicate that 90 GHz is an optimum frequency for this diagnostic. With 400 kW at the plasma and a 90* scattering angle, signal to noise ratios approaching 100 are possible for 0.5%n, alpha-particle fractions and 100 ms integration times. A millimeterwave system would be robust and adaptable to the ITER environment and access.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Notch Filter Options for ITER Stray Gyrotron Radiation

ITER will have multi megawatt gyrotron systems at 170, 120, and potentially at 60 GHz for ECH, current drive, NTM control, start up, and CTS diagnostics. The ITER environment will therefore have significant background levels of stay radiation at these frequencies that can pose a problem to a number of diagnostic systems. Several deep, narrowband reject filter approaches have been examined. Thes...

متن کامل

Impact of ICRH on the Measurement of Fast Ions by Collective Thomson Scattering in ITER

Collective Thomson scattering (CTS) has been proposed for measuring the phase space distribution of confined fast ion populations in ITER plasmas. This study determines the impact of fast ions accelerated by ion cyclotron resonance heating (ICRH) on the ability of CTS to diagnose fusion alphas in ITER. The investigated ICRH scenarios include pure second harmonic tritium heating and He minority ...

متن کامل

Preprint PFC/JA-83-3 RADIATION- MEASUREMENTS FROM A RIPPLED- FIELD MAGNETRON (CROSSED-IED--FEL)

We report measurements of millimeter wave emission from a rippled-field magnetron (crossed-field FEL). This is a novel source of coherent radiation in which electrons move in quasi-circular orbits under the combined action of a radial electric field, a uniform axial magnetic field and an azimuthally periodic wiggler magnetic field. We observe %300kW of RF power in a spectral line whose frequenc...

متن کامل

PFC / JA - 92 - 13 Performance Evaluation of the TFTR Gyrotron CTS Diagnostic for Alpha Particles

A large-angle, 60 GHz collective Thomson scattering (CTS) diagnostic system for localized measurements of DT alpha-particle velocity distribution and fraction is being implemented on TFTR. Calculations of expected CTS spectra, signal to noise ratio per receiver channel, and estimated error in determining the temperature and fraction of alpha-particles are being carried out. The experimental spe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014