Comparison of a drug-eluting balloon first and then bare metal stent with a drug-eluting stent for treatment of de novo lesions: study protocol of a randomized controlled trial

نویسندگان

  • Sang-Don Park
  • Chang-Hwan Yoon
  • Il-Young Oh
  • Jung-Won Suh
  • Young-Suk Cho
  • Tae-Jin Youn
  • Dong-Ju Choi
  • In-Ho Chae
چکیده

BACKGROUND The use of a drug-eluting balloon for the treatment of de novo coronary artery lesions remains to be evaluated. A previous trial in patients with stable and unstable angina comparing a bare metal stent mounted on a drug-eluting balloon with a sirolimus-eluting stent failed to meet the prespecified non-inferiority criteria versus the sirolimus-eluting stent. The stent struts of a bare metal stent pre-mounted on a drug-eluting balloon may prevent the appropriate delivery of drugs to the vessel wall and may result in reduced efficacy. In the present study we will therefore evaluate the efficacy of a drug-eluting balloon for treating de novo coronary artery lesions using a strategy designed to uniformly deliver drug to the vessel with a bare metal stent. METHODS/DESIGN The Comparison of Drug-Eluting Balloon first study is a prospective, randomized, open-label trial designed to demonstrate the non-inferiority of first using a drug-eluting balloon (Sequent please; B. Braun, Melsungen, Germany) followed by a bare metal stent (Coroflex Blue; B. Braun) compared with using a drug-eluting stent (Resolute Integrity; Boston Scientific, Natick, MA, USA) for de novo coronary artery lesions. The primary endpoint of the study is in-segment late loss at 9 months measured by quantitative coronary angiography. Secondary endpoints include angiographic findings such as angiographic success, device success, binary angiographic restenosis, and clinical outcomes such as procedural success, all-cause death, myocardial infarction, target vessel revascularization, target lesion revascularization, and stent thrombosis. A total of 180 patients will be enrolled in the study. DISCUSSION The Comparison of Drug-Eluting Balloon first study will evaluate the clinical efficacy, angiographic outcomes and safety of a drug-eluting balloon first followed by a bare metal stent compared with a drug-eluting stent for the treatment of de novo coronary artery lesions. TRIAL REGISTRATION Clinical Trials.gov: NCT01539603.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erratum to: Comparison of a drug-eluting balloon first and then bare metal stent with a drug-eluting stent for treatment of de novo lesions: study protocol of a randomized controlled trial

Unfortunately, the original version of this article [1] contained an error. The correct paragraph can be found below: The calculation of number of patients was not correct. It was wrote the non-inferiority margin as 0.1 mm. But it was 0.19 mm in an original document. Non-inferiority margin in previous coronary intervention studies has been set between 0.1 ~ 0.2 mm. The 0.19 mm is not irrelevant...

متن کامل

INtimal hyPerplasia evAluated by oCT in de novo COROnary lesions treated by drug-eluting balloon and bare-metal stent (IN-PACT CORO): study protocol for a randomized controlled trial

BACKGROUND Neointimal hyperplasia plays a pivotal role in the pathogenesis of in-stent restenosis in patients undergoing percutaneous coronary interventions. Drug-eluting balloons are a promising tool to prevent restenosis after coronary angioplasty. Moreover, an increased knowledge of the pathophysiology of restenosis my help improve therapeutic strategies. METHODS/DESIGN We present the desi...

متن کامل

Comparison of Drug-Eluting Balloon Followed by Bare Metal Stent with Drug-Eluting Stent for Treatment of de Novo Lesions: Randomized, Controlled, Single-Center Clinical Trial

The combined use of a drug-eluting balloon (DEB) and a bare metal stent (BMS) for the treatment of de novo non-small vessel coronary artery diseases (CAD) remains to be evaluated. We investigated the efficacy of a sequential treatment using a DEB together with a BMS implantation in comparison to a zotarolimus-eluting stent (ZES). This study was a prospective, randomized, open-label study. We de...

متن کامل

Rationale and design for the PAINT randomized trial.

BACKGROUND We describe the rationale and design for the 'PercutAneous INTervention with biodegradable-polymer based paclitaxel-eluting or sirolimus-eluting versus bare stents for de novo coronary lesions - PAINT trial'. OBJECTIVES To evaluate two novel formulations of paclitaxel-eluting stent and the sirolimus-eluting stent against a stent with the same metallic structure but without polymer ...

متن کامل

5-year clinical outcomes after sirolimus-eluting stent implantation insights from a patient-level pooled analysis of 4 randomized trials comparing sirolimus-eluting stents with bare-metal stents.

OBJECTIVES Five-year clinical follow-up has been scheduled per protocol by the 4 Cypher (Cordis/Johnson & Johnson, Warren, New Jersey) sirolimus-eluting stent (SES) versus bare-metal stent (BMS) randomized trials. BACKGROUND A delayed arterial healing response after drug-eluting stent implantation has raised concerns about the long-term safety of drug-eluting stents. METHODS In a pooled ana...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013