Arc fault is the arc that may cause damage to the society. Arc is with high temperature and massive heat. If arc fault appears in the low voltage supply environment, it will lead to fire or disaster. So detection and protection of arc fault is essential. In order to prevent the damage of fault arc, a new apparatus named Arc Fault Circuit Interrupter (AFCI) has been proposed. In the paper, arc fault features of the circuit with different load are studied. Then an arc fault detection method is proposed. Then a low cost AFCI is designed so as to promote AFCI. Experimental results show it has the ability to protect the arc fault.
منابع مشابه
Using Pv Module and Line Frequency Response Data to Create Robust Arc Fault Detectors
Photovoltaic (PV) systems have caused residential and commercial building fires when an electrical arc fault initiates in the conduction path. Article 690.11 in the United States 2011 National Electrical Code requires new photovoltaic systems on or penetrating a building to include a listed arc fault protection device to prevent additional fires. In response, manufacturers are creating arc faul...
متن کاملCharacterizing Pv Arcing Conditions with Impedance Spectroscopy and Frequency Response Analysis
Photovoltaic arc faults have led to a number of rooftop fires that have caused significant property damage and threatened the safety of building occupants. In response, Article 690.11 was added to the United States 2011 National Electrical Code, requiring new PV systems on or penetrating a building to include a listed arc fault protection device. Many proposed arc fault detectors utilize freque...
متن کاملVariable Speed Wind Turbine DFIG Back to Back Converters Open-Circuit Fault Diagnosis by Using of Combiniation Signal-Based and Model-Based Methodes
Condition monitoring (CM) and Fault Detection (FD) of wind turbine lead to increase in reliability and availability of turbine. IGBT open circuit of wind turbine converter will bring about depletion in output current of converter and as a result, reduction in production of wind turbine power. In this research, back to back converter IGBT open - gate fault for wind turbine based on DFIG is detec...
متن کاملLook up Table Based Low Power Analog Circuit Testing
In this paper, a method of low power analog testing is proposed. In spite of having Oscillation Based Built in Self-Test methodology (OBIST), a look up table based (LUT) low power testing approach has been proposed to find out the faulty circuit and also to sort out the particular fault location in the circuit. In this paper an operational amplifier, which is the basic building block in the ana...
متن کاملEffectiveness of Circuit Breakers in Mitigating Parallel Arcing Faults in the Home Run
NOTICE The issuance of this Report does not constitute an endorsement of any proposed amendment and in no way implies Listing, Classification, or other recognition by UL and does not authorize the use of UL Listing or Classification Marks or any other reference to Underwriters Laboratories Inc. on, or in connection with, the product. Underwriters Laboratories Inc., its employees, and its agents...
متن کامل