Cardiovascular magnetic resonance evaluation of aortic stenosis severity using single plane measurement of effective orifice area
نویسندگان
چکیده
BACKGROUND Transthoracic echocardiography (TTE) is the standard method for the evaluation of the severity of aortic stenosis (AS). Valve effective orifice area (EOA) measured by the continuity equation is one of the most frequently used stenotic indices. However, TTE measurement of aortic valve EOA is not feasible or not reliable in a significant proportion of patients. Cardiovascular magnetic resonance (CMR) has emerged as a non-invasive alternative to evaluate EOA using velocity measurements. The objectives of this study were: 1) to validate a new CMR method using jet shear layer detection (JSLD) based on acoustical source term (AST) concept to estimate the valve EOA; 2) to introduce a simplified JSLD method not requiring vorticity field derivation. METHODS AND RESULTS We performed an in vitro study where EOA was measured by CMR in 4 fixed stenoses (EOA = 0.48, 1.00, 1.38 and 2.11 cm²) under the same steady flow conditions (4-20 L/min). The in vivo study included eight (8) healthy subjects and 37 patients with mild to severe AS (0.72 cm² ≤ EOA ≤ 1.71 cm²). All subjects underwent TTE and CMR examinations. EOA was determinated by TTE with the use of continuity equation method (TTE(CONT)). For CMR estimation of EOA, we used 3 methods: 1) Continuity equation (CMR(CONT)); 2) Shear layer detection (CMR(JSLD)), which was computed from the velocity field of a single CMR velocity profile at the peak systolic phase; 3) Single plane velocity truncation (CMR(SPVT)), which is a simplified version of CMR(JSLD) method. There was a good agreement between the EOAs obtained in vitro by the different CMR methods and the EOA predicted from the potential flow theory. In the in vivo study, there was good correlation and concordance between the EOA measured by the TTE(CONT) method versus those measured by each of the CMR methods: CMR(CONT) (r = 0.88), CMR(JSLD) (r = 0.93) and CMR(SPVT) (r = 0.93). The intra- and inter- observer variability of EOA measurements was 5 ± 5% and 9 ± 5% for TTE(CONT), 2 ± 1% and 7 ± 5% for CMR(CONT), 7 ± 5% and 8 ± 7% for CMR(JSLD), 1 ± 2% and 3 ± 2% for CMR(SPVT). When repeating image acquisition, reproducibility of measurements was 10 ± 8% and 12 ± 5% for TTE(CONT), 9 ± 9% and 8 ± 8% for CMR(CONT), 6 ± 5% and 7 ± 4% for CMR(JSLD) and 3 ± 2% and 2 ± 2% for CMR(SPVT). CONCLUSION There was an excellent agreement between the EOA estimated by the CMR(JSLD) or CMR(SPVT) methods and: 1) the theoretical EOA in vitro, and 2) the TTE(CONT) EOA in vivo. The CMR(SPVT) method was superior to the TTE and other CMR methods in terms of measurement variability. The novel CMR-based methods proposed in this study may be helpful to corroborate stenosis severity in patients for whom Doppler-echocardiography exam is inconclusive.
منابع مشابه
Comparison between cardiovascular magnetic resonance and transthoracic doppler echocardiography for the estimation of effective orifice area in aortic stenosis
BACKGROUND The effective orifice area (EOA) estimated by transthoracic Doppler echocardiography (TTE) via the continuity equation is commonly used to determine the severity of aortic stenosis (AS). However, there are often discrepancies between TTE-derived EOA and invasive indices of stenosis, thus raising uncertainty about actual definite severity. Cardiovascular magnetic resonance (CMR) has e...
متن کاملUsefulness of cardiovascular magnetic resonance imaging for the evaluation of valve opening and closing kinetics in aortic stenosis.
AIMS The aims of this study were : (i) to determine the feasibility and reproducibility of the measurement of valve kinetic parameters by cardiovascular magnetic resonance (CMR) and (ii) to examine the association between these parameters and markers of a poor prognosis in patients with aortic stenosis (AS). METHODS AND RESULTS Eight healthy control subjects and 71 patients with AS (0.60 cm(2...
متن کاملQuantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation.
BACKGROUND The aim of this study was to test the accuracy of an automated 3-dimensional (3D) proximal isovelocity surface area (PISA) (in vitro and patients) and stroke volume technique (patients) to assess mitral regurgitation (MR) severity using real-time volume color flow Doppler transthoracic echocardiography. METHODS AND RESULTS Using an in vitro model of MR, the effective regurgitant or...
متن کاملDiscrepancies between cardiovascular magnetic resonance and Doppler echocardiography in the measurement of transvalvular gradient in aortic stenosis: the effect of flow vorticity
BACKGROUND Valve effective orifice area EOA and transvalvular mean pressure gradient (MPG) are the most frequently used parameters to assess aortic stenosis (AS) severity. However, MPG measured by cardiovascular magnetic resonance (CMR) may differ from the one measured by transthoracic Doppler-echocardiography (TTE). The objectives of this study were: 1) to identify the factors responsible for ...
متن کاملComparison of magnetic resonance imaging and cardiac catheterization in patients with suspected severe aortic stenosis.
OBJECTIVE Magnetic resonance imaging (MRI) is a novel technique used in the assessment of aortic stenosis. The aim of the study was to compare MRI and cardiac catheterization (CAT) that is still considered to be a "golden standard" in this indication. METHODS Thirty-four patients referred to CAT for the evaluation of aortic stenosis were enrolled into the study. CAT was performed according to...
متن کامل