Spring Cantilever: When and Why – A Clinical Report
نویسندگان
چکیده
H S Kiran Kumar1, Sudhakara Bhat2, Sanjay Gouda Patil3, Sankar Madhavan4, Rahul Kulkarni5 1Assistant Professor, Department of Prosthodontics, Sri Hasanamba Dental College and Hospital, Hassan, Karnataka, India, 2Professor and Head, Department of Prosthodontics, Sri Hasanamba Dental College and Hospital, Hassan, Karnataka, India, 3Professor, Department of Prosthodontics, Sri Hasanamba Dental College and Hospital, Hassan, Karnataka, India, 4Assistant Professor, Department of Prosthodontics, Sree Anjaneya Institute of Dental Sciences, Modakkallur, Atholi, Kozhikode, Kerala, India, 5Post-graduate, Department of Prosthodontics, Sri Hasanamba Dental College and Hospital, Hassan, Karnataka, India
منابع مشابه
A mechanical micro molecular mass sensor
One of the bio-sensing mechanisms is mechanical. Rather than measuring shift in resonance frequency, we adopt to measure the change in spring constant due to adsorption, as one of the fundamental sensing mechanism. This study explains determination of spring constant of a surface functionalized micro machined micro cantilever, which resonates in a trapezoidal cavity-on Silicon wafer, with the ...
متن کاملA mechanical micro molecular mass sensor
One of the bio-sensing mechanisms is mechanical. Rather than measuring shift in resonance frequency, we adopt to measure the change in spring constant due to adsorption, as one of the fundamental sensing mechanism. This study explains determination of spring constant of a surface functionalized micro machined micro cantilever, which resonates in a trapezoidal cavity-on Silicon wafer, with the ...
متن کاملAccurate Calibration and Uncertainty Estimation of the Normal Spring Constant of Various AFM Cantilevers
Measurement of force on a micro- or nano-Newton scale is important when exploring the mechanical properties of materials in the biophysics and nanomechanical fields. The atomic force microscope (AFM) is widely used in microforce measurement. The cantilever probe works as an AFM force sensor, and the spring constant of the cantilever is of great significance to the accuracy of the measurement re...
متن کاملA method for determining the spring constant of cantilevers for atomic force microscopy
Cantilevers fabricated by means of micromachining techniques are usually used for atomic force microscopy. In this paper, the spring constant of an atomic force microscope (AFM) cantilever is determined by using a large-scale cantilever. Since the spring constant of the large-scale cantilever is calibrated accurately, the spring constant of the AFM cantilever is determined precisely by measurin...
متن کاملDirect measurement of cantilever spring constants and correction for cantilever irregularities using an instrumented indenter.
A method is presented that allows direct measurement of a wide range of spring constants of cantilevers using an indentation instrument with an integrated optical microscope. An uncertainty of less than 10% can be achieved for spring constants from 0.1 to 10(2) Nm. The technique makes it possible to measure the spring constant at any desired location on a cantilever of any shape, particularly a...
متن کامل