BACKGROUND Individualizing mean arterial blood pressure (MAP) based on cerebral blood flow (CBF) autoregulation monitoring during cardiopulmonary bypass (CPB) holds promise as a strategy to optimize organ perfusion. The purpose of this study was to evaluate the accuracy of cerebral autoregulation monitoring using microcirculatory flow measured with innovative ultrasound-tagged near-infrared spectroscopy (UT-NIRS) noninvasive technology compared with transcranial Doppler (TCD). METHODS Sixty-four patients undergoing CPB were monitored with TCD and UT-NIRS (CerOx™). The mean velocity index (Mx) was calculated as a moving, linear correlation coefficient between slow waves of TCD-measured CBF velocity and MAP. The cerebral flow velocity index (CFVx) was calculated as a similar coefficient between slow waves of cerebral flow index measured using UT-NIRS and MAP. When MAP is outside the autoregulation range, Mx is progressively more positive. Optimal blood pressure was defined as the MAP with the lowest Mx and CFVx. The right- and left-sided optimal MAP values were averaged to define the individual optimal MAP and were the variables used for analysis. RESULTS The Mx for the left side was 0.31 ± 0.17 and for the right side was 0.32 ± 0.17. The mean CFVx for the left side was 0.33 ± 0.19 and for the right side was 0.35 ± 0.19. Time-averaged Mx and CFVx during CPB had a statistically significant "among-subject" correlation (r = 0.39; 95% confidence interval [CI], 0.22-0.53; P < 0.001) but had only a modest agreement within subjects (bias 0.03 ± 0.20; 95% prediction interval for the difference between Mx and CFVx, -0.37 to 0.42). The MAP with the lowest Mx and CFVx ("optimal blood pressure") was correlated (r = 0.71; 95% CI, 0.56-0.81; P < 0.0001) and was in modest within-subject agreement (bias -2.85 ± 8.54; 95% limits of agreement for MAP predicted by Mx and CFVx, -19.60 to 13.89). Coherence between ipsilateral middle CBF velocity and cerebral flow index values averaged 0.61 ± 0.07 (95% CI, 0.59-0.63). CONCLUSIONS There was a statistically significant correlation and agreement between CBF autoregulation monitored by CerOx compared with TCD-based Mx.
منابع مشابه
Intraoperative Cerebral Autoregulation Assessment Using Ultrasound-Tagged Near-Infrared-Based Cerebral Blood Flow in Comparison to Transcranial Doppler Cerebral Flow Velocity: A Pilot Study.
OBJECTIVE This was a pilot study comparing the ability of a new ultrasound-tagged near-infrared (UT-NIR) device to detect cerebral autoregulation (CA) in comparison to transcranial Doppler (TCD). DESIGN An unblinded, prospective, clinical feasibility study. SETTING Tertiary-care university hospital cardiac surgical operating rooms. PARTICIPANTS Twenty adult patients undergoing cardiac sur...
متن کاملMonitoring cerebral blood flow pressure autoregulation in pediatric patients during cardiac surgery.
BACKGROUND AND PURPOSE The limits of cerebral blood flow-pressure autoregulation have not been adequately defined for pediatric patients. Mean arterial blood pressure below these limits might contribute to brain injury during cardiac surgery. The purpose of this pilot study was to assess a novel method of determining the lower limits of pressure autoregulation in pediatric patients supported wi...
متن کاملContinuous assessment of cerebral autoregulation with near-infrared spectroscopy in adults after subarachnoid hemorrhage.
BACKGROUND AND PURPOSE In patients with subarachnoid hemorrhage, the assessment of cerebral autoregulation aids in prognosis as well as detection of vasospasm. Mx is a validated index of cerebral autoregulation based on measures of cerebral perfusion pressure and mean flow velocity on transcranial Doppler but is impractical for longer-term monitoring. Near-infrared spectroscopy is noninvasive a...
متن کاملAssessment of Cerebral Autoregulation Patterns with Near-infrared Spectroscopy during Pharmacological-induced Pressure Changes.
BACKGROUND Previous work has demonstrated paradoxical increases in cerebral oxygen saturation (ScO2) as blood pressure decreases and paradoxical decreases in ScO2 as blood pressure increases. It has been suggested that these paradoxical responses indicate a functional cerebral autoregulation mechanism. Accordingly, the authors hypothesized that if this suggestion is correct, paradoxical respons...
متن کاملReal-time continuous monitoring of cerebral blood flow autoregulation using near-infrared spectroscopy in patients undergoing cardiopulmonary bypass.
BACKGROUND AND PURPOSE Individualizing mean arterial blood pressure targets to a patient's cerebral blood flow autoregulatory range might prevent brain ischemia for patients undergoing cardiopulmonary bypass (CPB). This study compares the accuracy of real-time cerebral blood flow autoregulation monitoring using near-infrared spectroscopy with that of transcranial Doppler. METHODS Sixty adult ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 121 5 شماره
صفحات -
تاریخ انتشار 2015