Toward standardization of insulin immunoassays.

نویسندگان

  • W Greg Miller
  • Linda M Thienpont
  • Katleen Van Uytfanghe
  • Penelope M Clark
  • Patrik Lindstedt
  • Göran Nilsson
  • Michael W Steffes
چکیده

BACKGROUND Measurement of circulating insulin may improve the classification and management of diabetes mellitus and assist in treating people with insulin resistance. METHODS A work group convened by the American Diabetes Association evaluated results for a panel of 39 single donor sera measured by 10 commercial insulin methods from 9 manufacturers against an isotope dilution-liquid chromatography/tandem mass spectrometry (IDMS) measurement procedure calibrated using purified recombinant insulin. We used a candidate primary (pure substance) reference material, pooled serum, and single donor sera to evaluate approaches to achieve improved agreement of results between the routine and reference measurement procedures. RESULTS Four of 10 methods had >or=95% of individual serum results within 32% of the IDMS concentrations. However, the bias vs IDMS was more than 15.5% for 7 of 10 methods in 36%-100% of individual samples. A purified recombinant insulin preparation used as a common calibrator did not improve harmonization of results among routine methods but was not used as instructed by all participants. Calibration using serum pools achieved bias <15.5% for nearly all results in the concentration range covered by the pools (>60 pmol/L). Calibration using a panel of individual sera was the most effective to improve harmonization of results over the full measuring range. CONCLUSIONS Agreement among methods can be improved by establishing traceability to the IDMS procedure using a panel of native sera. Pooled sera may be useful as trueness control materials. The usefulness of the pure insulin primary reference material [candidate reference material for insulin (cRMI)] requires clarification of protocols used by manufacturers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Insulin immunoassays: fast approaching 50 years of existence and still calling for standardization.

Read more and get great! That's what the book enPDFd insulin immunoassays fast approaching 50 years of existence and still calling for standardization ed will give for every reader to read this book. This is an on-line book provided in this website. Even this book becomes a choice of someone to read, many in the world also loves it so much. As what we talk, when you read more every page of this...

متن کامل

Pilot study for the standardization of insulin immunoassays with isotope dilution liquid chromatography/tandem mass spectrometry.

BACKGROUND An international working group convened by the American Diabetes Association (ADA) called for a reference measurement procedure for use in a trueness-based standardization project of insulin immunoassays. In view of this demand, we conducted a pilot study to investigate the feasibility of such a standardization project with our isotope dilution-liquid chromatography/tandem mass spect...

متن کامل

Feasibility of standardization of serum C-peptide immunoassays with isotope-dilution liquid chromatography-tandem mass spectrometry.

BACKGROUND Serum C-peptide concentrations reflect pancreatic function in different clinical and diagnostic settings; however, the utility of C-peptide testing is limited by the lack of standardized commercial immunoassays. Standardization can best be done by split-sample comparison with a hierarchically higher reference measurement procedure with a set of native sera. For serum peptides, isotop...

متن کامل

Standardization of insulin immunoassays: report of the American Diabetes Association Workgroup.

BACKGROUND Circulating insulin concentration in serum or plasma provides important information for the estimation of insulin secretion and insulin resistance. Currently, lack of standardization of insulin assays hinders efforts to achieve consistent measures for treatment guidelines. METHODS A Workgroup convened by the American Diabetes Association evaluated 12 different commercial insulin me...

متن کامل

Issues in immunoassay standardization: the ARCHITECT Folate model for intermethod harmonization.

Extensive variability among folate assay methods has been well described. A FLAIR round-robin study of serum and whole-blood folate results across 11 laboratories in seven European countries reported overall CVs of 18–41% (1 ). A CDC round-robin survey of 20 laboratories reported twoto ninefold differences in folate values among methods and laboratories (2 ). With increasing awareness of the nu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 55 5  شماره 

صفحات  -

تاریخ انتشار 2009