Ambulatory Cardiac Monitoring for Discharged Emergency Department Patients with Possible Cardiac Arrhythmias

نویسندگان

  • Donald Schreiber
  • Ayesha Sattar
  • Dorian Drigalla
  • Steven Higgins
چکیده

INTRODUCTION Many emergency department (ED) patients have symptoms that may be attributed to arrhythmias, necessitating outpatient ambulatory cardiac monitoring. Consensus is lacking on the optimal duration of monitoring. We describe the use of a novel device applied at ED discharge that provides continuous prolonged cardiac monitoring. METHODS We enrolled discharged adult ED patients with symptoms of possible cardiac arrhythmia. A novel, single use continuous recording patch (Zio®Patch) was applied at ED discharge. Patients wore the device for up to 14 days or until they had symptoms to trigger an event. They then returned the device by mail for interpretation. Significant arrhythmias are defined as: ventricular tachycardia (VT) ≥4 beats, supraventricular tachycardia (SVT) ≥4 beats, atrial fibrillation, ≥3 second pause, 2nd degree Mobitz II, 3rd degree AV Block, or symptomatic bradycardia. RESULTS There were 174 patients were enrolled and all mailed back their devices. The average age was 52.2 (± 21.0) years, and 55% were female. The most common indications for device placement were palpitations 44.8%, syncope 24.1% and dizziness 6.3%. Eighty-three patients (47.7%) had ≥1 arrhythmias and 17 (9.8%) were symptomatic at the time of their arrhythmia. Median time to first arrhythmia was 1.0 days (IQR 0.2-2.8) and median time to first symptomatic arrhythmia was 1.5 days (IQR 0.4-6.7). 93 (53.4%) of symptomatic patients did not have any arrhythmia during their triggered events. The overall diagnostic yield was 63.2% CONCLUSION The Zio®Patch cardiac monitoring device can efficiently characterize symptomatic patients without significant arrhythmia and has a higher diagnostic yield for arrhythmias than traditional 24-48 hour Holter monitoring. It allows for longer term monitoring up to 14 days.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency of Cardiac Arrhythmias in Patients with Aluminum Phosphide Poisoning

Background: Cardiac failure is the major lethal consequence of aluminum phosphide (AlP) poisoning. This study was designed to determine the frequency of cardiac arrhythmias in patients with AlP poisoning. Methods: In this prospective cross-sectional study, patients with definitive history of AlP poisoning treated at emergency department of Allied Hospital Faisalabad, Faisalabad, Pakistan, from ...

متن کامل

Etiology of syncope in hospitalized patients

 Background: Syncope is a common clinical problem which can be remarkably debilitating and associated with high health care costs. Syncope is a clinical syndrome with many potential causes. The aim of the study was to determine the etiologies of patients with syncope in the emergency department (ED) of a referral and general university hospital.  Methods: One hundred sixty-five consecutive ...

متن کامل

Survival and outcomes following cardiopulmonary resuscitation; a descriptive study in Iran

Objective: Cardiopulmonary resuscitation (CPR) has been known in its present form since 1960. Different studies have reported variable outcomes among different countries. Therefore, the purpose of this study was to assess the rate of CPR success and the survival rate in managing cardiac arrest among patients in an educational medical center. Methods: Th...

متن کامل

Utility of in-hospital cardiac remote telemetry in patients with unexplained syncope.

AIMS Cardiac remote telemetry (CR-TEL) is in wide use in cardiac units, but its diagnostic value in the setting of unexplained syncope is unknown. METHODS One hundred and two consecutive patients (73 +/- 14 years) arriving to the emergency department due to an unexplained syncope were admitted under CR-TEL. Heart rhythm was continuously monitored from a central station by trained nurses. Even...

متن کامل

Holter monitoring and cardiac event recording.

The detection and characterization of transient arrhythmias is possible with continuous ambulatory electrocardiography (Holter monitoring) or cardiac event recording. These techniques have significantly increased our appreciation of transient arrhythmias, often undetected with routine echocardiography and have provided highly sensitive means to assess need and efficacy of antiarrhythmic therapy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014