Differences in the INR evaluation of two different thromboplastins in patients with positivity to lupus anticoagulant in ongoing oral anticoagulation
نویسندگان
چکیده
BACKGROUND A possible interference between lupus anticoagulant (LAC), a well characterized clotting inhibitor, in the International Normalized Ratio (INR) determination during oral anticoagulation (OA) has been reported in the literature. Few data are available about the relationship between this kind of interference and the daily clinical management of oral anticoagulation. The aim of the study is to evaluate the role of two different thromboplastins-RecombiPlasTin 2G and HepatoComplex-in the determination of INR values of several patients' ongoing OA for a previous thrombotic disorder with and without positivity to LAC, and to evaluate possible interferences in the daily therapeutic approach. PATIENTS AND METHODS We selected 16 patients (13 females and 3 males, mean age 59 ± 16 years) with LAC positivity ongoing OA and 11 control subjects (7 females and 4 males, mean age 58 ± 14.5 years) with similar characteristics (ie, ethnic background and weight) with LAC negativity ongoing OA. 165 assays for INR determination were analyzed from both groups. Statistical analysis was performed using STATA 10 software. P values were considered significant if <0.05. RESULTS Mean values of INR for patients with LAC positivity were 3.79 ± 1.63 when tested with RecombiPlasTin 2G vs 3.18 ± 1.15 when tested with HepatoComplex (P < 0.001, s); while mean values of INR for patients with antiphospholipid syndrome (APS) with LAC negativity were 3.54 ± 1.39 when tested with RecombiPlasTin 2G vs 3.23 ± 1.14 when tested with HepatoComplex (P < 0.002, s). An INR value > than 4.5 was found in 31/165 samples in 9 subjects, 8 patients with LAC positivity, and 1 control group subject with LAC negativity. There was a great difference in INR values in these subjects if we use the common thromboplastin (ie, RecombiPlasTin 2G) with a INR range varying from 5.14 ± 0.35 vs 3.79 ± 0.38 if we use another thromboplastin (ie, HepatoComplex) (P < 0.001, s). A change in the therapeutic approach for OA is possible in these cases because different INR values were obtained using different thromboplastins. DISCUSSION Our data confirm that INR evaluation does not reveal significant changes also if tested with two different thromboplastins, for patients ongoing OA with and without LAC positivity, when the INR value is < than 4. Over this INR value there is a significant difference in patients with LAC positivity if we use a different thromboplastin for the INR determination. For this reason values obtained by RecombiPlasTin 2G need to be confirmed and matched with another thromboplastin (ie, HepatoComplex). This approach may be useful in order to have a good INR testing for the chronic long-term treatment with OA in particular in patients with LAC positivity.
منابع مشابه
Recombinant thromboplastins vs tissue-extract thromboplastins in patients on unstable oral anticoagulant therapy.
In a previous report in Clinical Chemistry, we described much higher international normalized ratios (INRs) with recombinant Neoplastin R (Roche Diagnostics) than with tissue-extract Neoplastin Plus (Roche Diagnostics) in patients initiating oral anticoagulant therapy (1 ). For patients on stable oral anticoagulation, we observed no significant differences in INRs between the thromboplastins. T...
متن کاملA critical evaluation of the prothrombin time for monitoring oral anticoagulant therapy.
The Quick prothrombin time is the most common clotting test performed, principally for monitoring oral anticoagulant therapy. The International Normalized Ratio (INR) for comparing patient results from prothrombin time measurements and the International Standardized Index (ISI) for achieving greater consistency of results using different thromboplastins have made it possible to compare the resu...
متن کاملInterference of lupus anticoagulants in prothrombin time assays: implications for selection of adequate methods to optimize the management of thrombosis in the antiphospholipid-antibody syndrome.
BACKGROUND AND OBJECTIVE Prolonged anticoagulation aiming at International Normalized Ratio (INR) values > 3.0 has been recommended for patients with thrombosis and the antiphospholipid-antibody syndrome. We evaluated the influence of anticoagulant antibodies in two different prothrombin time (PT) assays carried out on plasma from lupus anticoagulant patients on oral anticoagulation. DESIGN A...
متن کاملComparison between Prothrombin Complex Concentrate (PCC) and Fresh Frozen Plasma (FFP) for the Urgent Reversal of Warfarin in Patients with Mechanical Heart Valves in a Tertiary Care Cardiac Center
Fresh frozen plasma (FFP) and prothrombin complex concentrate (PCC) reverse oral anticoagulants such as Warfarin. We compared the standard dosage FFP and PCC in terms of efficacy and safety for patients with mechanical heart valves undergoing interventional procedures while receiving Warfarin. Fifty patients were randomized (25 for each group) with mechanical heart valves [international normali...
متن کاملComparison between Prothrombin Complex Concentrate (PCC) and Fresh Frozen Plasma (FFP) for the Urgent Reversal of Warfarin in Patients with Mechanical Heart Valves in a Tertiary Care Cardiac Center
Fresh frozen plasma (FFP) and prothrombin complex concentrate (PCC) reverse oral anticoagulants such as Warfarin. We compared the standard dosage FFP and PCC in terms of efficacy and safety for patients with mechanical heart valves undergoing interventional procedures while receiving Warfarin. Fifty patients were randomized (25 for each group) with mechanical heart valves [international normali...
متن کامل