Technique for controlling the cement for an implant crown.
نویسندگان
چکیده
The Journal of Prosthetic Dentistry Londono and Marafie Wadhwani and Piñeyro Cementation of an implant prosthesis is an accepted protocol. Less demanding surgical placement of the implant, simpler laboratory techniques, passive fit, esthetics, and control of the occlusion are among some of the advantages.1 However, disadvantages include unpredictable retention and resistance and the detrimental effect of cement flow into the soft tissues that can be difficult to remove. The soft tissue attachment onto the implant surface is more delicate than that seen at the natural tooth surface due to the lack of Sharpey fiber insertion, the reduced number of collagen fibers, and the direction in which these fibers run.2 Cement extrusion into the sulcular area may result in soft tissue swelling, soreness, and bleeding or exudation on probing.3 In some instances, the excess cement has been considered to be the cause of implant failure.4 Removal of excess cement with plastic and metal scalers may result in scratches and gouges on the implant surfaces.5 Control of cement volume has been documented previously using the ITI solid abutment (Straumann USA, Andover, Mass).6 This requires an implant analog or practice abutment, as described by the authors.6 When a custom abutment is to be used under the crown, this becomes more challenging. The dental laboratory may be instructed to make a duplicate analog using an acrylic resin, but this is time consuming for the technician and involves additional laboratory costs. Technique for controlling the cement for an implant crown
منابع مشابه
An esthetic solution to the screw-retained implant restoration: introduction to the implant crown adhesive plug: clinical report.
UNLABELLED Screw-retained implant crowns may be clinically demanding, especially managing the esthetic and occlusal challenges of screw access channel closure. Many clinicians have moved away from using screw retention as a means of fixing a crown to an implant in favor of cementation to an underlying abutment. A link has been established between peri-implant disease and excess cement extrusion...
متن کاملCement-Implant Interface Fracture Failure by Crack Initiation Due to Interface Cavity Stress Concentration
Nowadays total joint replacements are widely used in the world, so in average 800,000 joint surgeries are done yearly only in Europe and North America. However implant loosening is and remains as the major issue of all implant failures and therefore causes revision surgery procedures. Studies and experiments have identified poor fixation of implants most likely is the main cause of long term im...
متن کاملExtraoral Cementation Technique to Minimize Cement-Associated Peri-implant Marginal Bone Loss: Can a Thin Layer of Zinc Oxide Cement Provide Sufficient Retention?
This report describes the use of laboratory-fabricated crown intaglio replicas for extraorally prepared cementation of fixed restorations to implants. This technique minimizes excess cement and may therefore reduce the risk of cement-related marginal peri-implant bone loss. It is unclear whether the remaining thin layer of luting agent provides sufficient retention if low-adhesive zinc oxide (Z...
متن کاملAn introduction to the implant crown with an esthetic adhesive margin (ICEAM).
UNLABELLED This article describes a novel technique with the addition of a pressed porcelain abutment margin capable of bonding to the porcelain margin of an implant crown restoration. This allows for supragingival margin placement, reduces the potential effect of excess cement-induced peri-implant disease, and provides a controlled environment for the bonding process. Another advantage is the ...
متن کاملVertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents
OBJECTIVES This study aimed to evaluate the vertical discrepancy of implant-supported crown structures constructed with vacuum-casting and Direct Metal Laser Sintering (DMLS) technologies, and luted with different cement types. STUDY DESIGN Crown copings were fabricated using: (1) direct metal laser sintered Co-Cr (LS); (2) vacuum-cast Co-Cr (CC); and (3) vacuum-cast Ti (CT). Frameworks were ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of prosthetic dentistry
دوره 102 1 شماره
صفحات -
تاریخ انتشار 2009