Can Spherical Deconvolution give us more information beyond fibre orientation? Towards novel quantifications of white matter integrity

نویسندگان

  • F. Dell'Acqua
  • A. Simmons
  • S. Williams
  • M. Catani
چکیده

Introduction In recent years Spherical Deconvolution (SD) methods have been applied to diffusion imaging to improve the visualization of multi-fibre orientation in brain regions with complex white matter organization [1][2][3]. However, the potential to quantify white matter integrity with SD has not been explored. Previous simulations have shown that the variation of fibre diffusion properties affects the amplitude of the recovered fibre orientation density function but not its orientation [1][2]. This suggests that the amplitude of the fibre orientation can provide additional information about fibre microstructure. In this study we investigate, using a model of restricted diffusion inside a cylinder, how the variation in the axonal diameters affects the fibre response profile and consequently the amplitude of the estimated fibre orientation. Methods The attenuation of the diffusion signal was estimated first along the radial direction of the fibre for different axonal diameters (from 2 μm to 40 μm) with an intra-axonal diffusivity assumed equal to Dfibre=1.5x10 mm/s. A Pulsed Gradient Spin Echo sequence was simulated imposing a diffusion gradient setup close to a real sequence adopted for acquiring SD data on a clinical scanner (Δ=40 ms, δ=30 ms, Gradient Amplitude=40 mT/m, b-value ∼3000 mm/s). In order to include the effects of finite diffusion gradient pulses, two signal models of restricted diffusion were taken into account: the model proposed by Van Gelderen [4] based on the Gaussian Phase Approximation (GPA) and the Multiple Correlation Function (MCF) approach introduced by Grebenkov [5]. Assuming a statistical independence of the net displacement of water molecules along the axis and the radial direction of the fibre, the fibre signal profile for different axonal diameters was then estimated as Efibre(q,Δ)=E//(q//,Δ)E⊥(q⊥,Δ) according to [6]. E//(q//,Δ) is the signal attenuation along the axis of the fibre and it is modelled as free 1D-Gaussian diffusion; E⊥(q⊥,Δ) is the signal attenuation measured perpendicular to the fibre orientation and it is modelled with the previous restricted diffusion models. Here, q// and q⊥ are the components of the q-vector decomposed along the parallel and the perpendicular direction of the fibre. To remove scaling factors in fibre responses each fibre signal profile was normalized to its corresponding maximum signal amplitude. SD was performed according to [3] on the original fibre signal profiles by imposing as fibre response both the exact normalized signal profile and an arbitrary normalized fibre response assumed with a fixed axonal diameter. Finally, spherical deconvolution was performed on a fibre-crossing configuration where, for one of the two fibres, different axonal diameters (fibre1=6, 12, 18 μm, fibre2=12 μm) and different volume fractions (fibre1=0.7 0.5 0.3, fibre2=0.3 0.5 0.7) were assumed. Results Figure 1 shows that with the chosen experimental setup the two models of restricted diffusion (GPA and MCF) provide similar signal attenuations. Larger differences between the two models appear for larger axonal diameters when the signal is also close to the noise floor level typically measured on clinical scanners (SNRb=0 =15). Figure 2 shows that the original 2D-fibre signal profiles exhibit a large decrease in the signal amplitude along the radial direction of the fibre for increasing axonal diameters. On the contrary, the normalized fibre response profiles show little differences for diameters smaller than 16 μm (blue profiles) while “fatter” profiles become evident for larger diameters (red profiles). This result suggests that for smaller diameters signal differences are mainly related to the scale of the signal profiles more than its shape. Figure 3 shows the maximum amplitude of the fibre orientations obtained deconvolving the signal from fibres with increasing axonal diameter by imposing both the exact and the fixed (axonal diameter=16 μm) fibre responses. By applying normalized fibre responses the amplitude of the recovered fibre orientation is rescaled showing a monotonic decrease for increasing axonal diameters. The choice of a fixed fibre response produces similar results, although the amplitude for large diameters is underestimated compared to the exact fibre response. Figure 4 shows the amplitudes of the recovered fibre orientation for the fibre-crossing configuration for different volume fractions and axonal diameters. The amplitude of the recovered fibre orientation increases with increasing volume fraction of the fibre or with decreasing fibre diameter. Discussion and conclusion This study suggests that variations in the amplitude of the recovered fibre orientation can reflect not only differences in the volume fraction of the fibre but also changes in the intrinsic structural properties of the fibres, such as the axonal diameter. The amplitude of the recovered fibre orientation could provide, therefore, useful clinical information in several white matter conditions including motor neuron disease, Wallerian degeneration and in demyelinating disorders where the increased displacement of water molecules due to the myelin degeneration might also be seen, in first approximation, as an “apparent” increase of the axonal diameter [7]. In all these conditions, changes in white matter properties will be also reflected as changes in the amplitude of the corresponding fibre orientation. Moreover, in comparison with previous indices of white matter integrity that provide only an average description from each voxel, the amplitude of the recovered fibre orientation is also specific to the single fibre orientation and therefore less susceptible of partial volume effects. In conclusion assuming a fibre response function based on a restricted diffusion model may lead to a better interpretation of spherical deconvolution results, relaxing the requirement of an exact knowledge of the fibre response and possibly help the development of new fibre specific indices of white matter integrity. References: [1] Tournier JD et al. NeuroImage 23:1176-1185 (2004); [2] Anderson AW, MRM 54:1194-1206, (2005); [3] Dell’Acqua F et al. IEEE TBME 54(3):462472, (2007); [4] Van Gelderen P et al. J Magn Reson Ser B 103:255–260 (1994); [5] D. S. Grebenkov, Rev. Mod. Phys. 79, 1077 (2007); [6] Assaf Y et al. MRM 52:965–978 (2004); [7] Assaf Y et al. MRM 23:703 – 710 (2005).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved tractography using asymmetric fibre orientation distributions

Diffusion MRI allows us to make inferences on the structural organisation of the brain by mapping water diffusion to white matter microstructure. However, such a mapping is generally ill-defined; for instance, diffusion measurements are antipodally symmetric (diffusion along x and -x are equal), whereas the distribution of fibre orientations within a voxel is generally not symmetric. Therefore,...

متن کامل

Can spherical deconvolution provide more information than fiber orientations? Hindrance modulated orientational anisotropy, a true-tract specific index to characterize white matter diffusion.

Diffusion tensor imaging (DTI) methods are widely used to reconstruct white matter trajectories and to quantify tissue changes using the average diffusion properties of each brain voxel. Spherical deconvolution (SD) methods have been developed to overcome the limitations of the diffusion tensor model in resolving crossing fibers and to improve tractography reconstructions. However, the use of S...

متن کامل

Diffusion Gradient Calibration Influences the Accuracy of Fibre Orientation Density Function Estimation: Validation by Efficiency Measure

Introduction. Diffusion-weighted (DW) MRI provides important information regarding the arrangement of white matter fibres. However, imperfections in the DW gradients may cause errors in the estimation of diffusion parameters. The sources of the gradient errors are various and may arise from long-term eddy currents, background gradients, imaging gradients, and spatial non-linearity and non-unifo...

متن کامل

Multiple Fibres: Beyond the diffusion tensor

This chapter covers techniques for resolving multiple fibre populations in each voxel, as well as methods to exploit the information they recover. It begins by describing the limitations of DTI and the problems that complex white-matter configurations such as crossing fibre-populations and bending fibres present. It then goes on to describe multiple-tensor models, diffusion spectrum imaging, QB...

متن کامل

Reduced Encoding Persistent Angular Structure

Introduction Persistent angular structure (PAS) MRI [1] is one of many approaches that recover complex white matter fibre configurations within single voxels of high angular resolution diffusion MRI (HARDI) data. It continues to exhibit impressive performance compared to other state of the art methods [2], but at the expense of unreasonably long reconstruction times. Here, we propose and test a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009