[Oxygen-enhanced MRI of the lung: optimized calculation of difference images].

نویسندگان

  • O Dietrich
  • C Losert
  • U Attenberger
  • C Reuter
  • U Fasol
  • M Peller
  • K Nikolaou
  • M F Reiser
  • S O Schoenberg
چکیده

BACKGROUND In oxygen-enhanced lung MRI, difference maps of acquisitions during inhalation of room air and pure oxygen are calculated to assess lung function. The purpose of this study was to analyze how the calculation of these difference maps depends on the delayed signal change after switching the gas supply. METHODS Ten healthy volunteers were examined with an ECG and respiratory-triggered T1-weighting inversion recovery HASTE sequence with parallel imaging. Four blocks with 20 repetitions of up to 6 coronal slices were continuously acquired; in blocks 1 and 3 room air was supplied, in blocks 2 and 4 oxygen. Data were postprocessed, discarding between 0 and 19 repetitions after each change of gas supply before calculating the relative signal difference. RESULTS The averaged relative signal difference increases from 9.4 to 17.4% when the number of discarded acquisitions increases; the ratio of signal difference and spatial standard deviation reaches a maximum at 5-8 discarded acquisitions. CONCLUSIONS An optimized ratio of signal difference and statistical error is found if about 5-8 of 20 respiratory-triggered repetitions are discarded after each change of gas supply for the calculation of difference maps.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lung imaging using oxygen-enhanced MRI in small animals

BACKGROUND Oxygen enhanced magnetic resonance imaging (OE-MRI) is a novel method of assessing regional ventilation and oxygen diffusion from the alveoli into the capillaries of the lung. The paramagnetic nature of oxygen and deoxyhemoglobin in blood shortens the T1 of the oxygenated tissues. MRI can visualize the effect by a signal increase on T1 weighted images acquired with subjects during br...

متن کامل

The change of longitudinal relaxation rate in oxygen enhanced pulmonary MRI depends on age and BMI but not diffusing capacity of carbon monoxide in healthy never-smokers

OBJECTIVE Oxygen enhanced pulmonary MRI is a promising modality for functional lung studies and has been applied to a wide range of pulmonary conditions. The purpose of this study was to characterize the oxygen enhancement effect in the lungs of healthy, never-smokers, in light of a previously established relationship between oxygen enhancement and diffusing capacity of carbon monoxide in the l...

متن کامل

Improvement of multislice oxygen-enhanced MRI of the lung by fully automatic non-rigid image registration.

PURPOSE In oxygen-enhanced magnetic resonance imaging of the lung (O2-MRI), motion artifacts related to breathing hamper the quality of the parametric O2-maps. In this study, fully automatic non-rigid image registration was assessed as a post-processing method to improve the quality of O2-MRI. MATERIALS AND METHODS Twenty healthy volunteers were investigated on a 1.5 T MR system. O2-MRI was o...

متن کامل

Calculation of total dose and dose equivalent distribution in the treatment of lung cancer using MR-guided carbon therapy

Nowadays, in order to improve the accuracy of treatment in radiation therapy, there are many attempts to use magnetic resonance imaging (MRI) due to the advantages of excellent soft tissue contrast and ultra-fast pulse sequences. On the other hand, carbon-ion radiation therapy is developing rapidly due to the benefits of greater relative biological effectiveness (RBE) and the application in the...

متن کامل

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Der Radiologe

دوره 46 4  شماره 

صفحات  -

تاریخ انتشار 2006