Subfemtotesla scalar atomic magnetometry using multipass cells.
نویسندگان
چکیده
Scalar atomic magnetometers have many attractive features but their sensitivity has been relatively poor. We describe a Rb scalar gradiometer using two multipass optical cells. We use a pump-probe measurement scheme to suppress spin-exchange relaxation and two probe pulses to find the spin precession zero crossing times with a resolution of 1 psec. We realize a magnetic field sensitivity of 0.54 fT/Hz(1/2), which improves by an order of magnitude the best scalar magnetometer sensitivity and exceeds, for example, the quantum limit set by the spin-exchange collisions for a scalar magnetometer with the same measurement volume operating in a continuous regime.
منابع مشابه
Cavity enhanced atomic magnetometry
Atom sensing based on Faraday rotation is an indispensable method for precision measurements, universally suitable for both hot and cold atomic systems. Here we demonstrate an all-optical magnetometer where the optical cell for Faraday rotation spectroscopy is augmented with a low finesse cavity. Unlike in previous experiments, where specifically designed multipass cells had been employed, our ...
متن کاملSparse Multipass 3D SAR Imaging: Applications to the GOTCHA Data Set
Typically in SAR imaging, there is insufficient data to form well-resolved three-dimensional (3D) images using traditional Fourier image reconstruction; furthermore, scattering centers do not persist over wide-angles. In this work, we examine 3D non-coherent wide-angle imaging on the GOTCHA Air Force Research Laboratory (AFRL) data set; this data set consists of multipass complete circular aper...
متن کاملRelaxivity of gadolinium complexes detected by atomic magnetometry.
Laser atomic magnetometry is a portable and low-cost yet highly sensitive method for low magnetic field detection. In this work, the atomic magnetometer was used in a remote-detection geometry to measure the relaxivity of aqueous gadolinium-diethylenetriamine pentaacetic acid Gd(DTPA) at the Earth's magnetic field (40 μT). The measured relaxivity of 9.7±2.0 s(-1) mM(-1) is consistent with field...
متن کاملBanach Pair Frames
In this article, we consider pair frames in Banach spaces and introduce Banach pair frames. Some various concepts in the frame theory such as frames, Schauder frames, Banach frames and atomic decompositions are considered as special kinds of (Banach) pair frames. Some frame-like inequalities for (Banach) pair frames are presented. The elements that participant in the construction of (Ba...
متن کاملQuantum Kalman filtering and the Heisenberg limit in atomic magnetometry.
The shot-noise detection limit in current high-precision magnetometry [Nature (London) 422, 596 (2003)] is a manifestation of quantum fluctuations that scale as 1/sqrt[N] in an ensemble of N atoms. Here, we develop a procedure that combines continuous measurement and quantum Kalman filtering [Rep. Math. Phys. 43, 405 (1999)]] to surpass this conventional limit by exploiting conditional spin squ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physical review letters
دوره 110 16 شماره
صفحات -
تاریخ انتشار 2013