Strain and strain rate parametric imaging. A new method for post processing to 3-/4-dimensional images from three standard apical planes. Preliminary data on feasibility, artefact and regional dyssynergy visualisation
نویسندگان
چکیده
BACKGROUND We describe a method for 3-/4D reconstruction of tissue Doppler data from three standard apical planes, post processing to derived data of strain rate/strain and parametric colour imaging of the data. The data can be displayed as M-mode arrays from all six walls, Bull's eye projection and a 3D surface figure that can be scrolled and rotated. Numerical data and waveforms can be re-extracted. METHODS Feasibility was tested by Strain Rate Imaging in 6 normal subjects and 6 patients with acute myocardial infarction. Reverberation artefacts and dyssynergy was identified by colour images. End systolic strain, peak systolic and mid systolic strain rate were measured. RESULTS Infarcts were visualised in all patients by colour imaging of mid systolic strain rate, end systolic strain and post systolic shortening by strain rate. Reverberation artefacts were visible in 3 of 6 normals, and 2 of 6 patients, and were identified both on bull's eye and M-mode display, but influenced quantitative measurement. Peak systolic strain rate was in controls minimum -1.11, maximum -0.89 and in patients minimum -1.66, maximum 0.02 (p = 0.04). Mid systolic strain rate and end systolic strain did not separate the groups significantly. CONCLUSION 3-/4D reconstruction and colour display is feasible, allowing quick visual identification of infarcts and artefacts, as well as extension of area of post systolic shortening. Strain rate is better suited to colour parametric display than strain.
منابع مشابه
Preliminary clinical study of left ventricular myocardial strain in patients with non-ischemic dilated cardiomyopathy by three-dimensional speckle tracking imaging
BACKGROUND Non-ischemic dilated cardiomyopathy (DCM) is the most common cardiomyopathy worldwide, with significant mortality. Correct evaluation of the patient's myocardial function has important clinical significance in the diagnosis, therapeutic effect assessment and prognosis in non-ischemic DCM patients. This study evaluated the feasibility of three-dimensional speckle tracking imaging (3D-...
متن کاملTwo-dimensional strain to assess regional left and right ventricular longitudinal function in 100 normal foetuses.
AIMS Previous reports have demonstrated that myocardial velocities are not sufficiently sensitive in foetal heart studies. Strain (S) imaging is a new non-invasive ultrasonic technique able to quantify regional myocardial deformation properties. Strain imaging has a superior sensitivity than myocardial velocity for non-invasive assessment of ventricular function. However, Doppler-derived strain...
متن کاملAn Effective 3-Dimensional Regional Myocardial Strain Computation Method with Displacement ENcoding with Stimulated Echoes (DENSE) in Dilated Cardiomyopathy Patients and Healthy Subjects
Fast Cine Displacement ENcoding with Stimulated Echoes (DENSE) is a magnetic resonance imaging (MRI) technique attributed with higher spatial resolution and rapid post-processing. Our primary goal was three-dimensional (3D) regional strains quantification using DENSE images in healthy subjects and non-ischemic, non-valvular dilated cardiomyopathy (DCM) patients, followed by validation with comp...
متن کاملThe Strain Dependence of Post-Deformation Softening during the Hot Deformation of 304H Stainless Steel
Experiments were carried out in which the dependence of the fractional softening on temperature, time and strain rate was determined in a 304H stainless steel. Three prestrain ranges were identified pertaining to three different post-deformation softening behaviors: 1) prestraining to below the DRX critical strain: strongly strain dependent softening by SRX alone with softening kinetics control...
متن کاملUsing a photographic image processing method as a part of the QA program in some radiotherapy departments where CTs are involved with COVID-19 patients
Background & Aims: Owing to the significant role of CT images in diagnosis and follow up of patients affected with coronavirus, the imaging section of cancer centers in some countries engaged in providing services to COVID-19 patients. The aim of this study was to introduce a CT-independent photographic-based QA method in some radiotherapy departments where CTs are involved with COVID-19 patien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiovascular Ultrasound
دوره 1 شماره
صفحات -
تاریخ انتشار 2003