Superconducting Fault Current Limiter in DC Systems with MLI Fed to IM
نویسنده
چکیده
In this paper, an application of superconducting fault current limiter (SFCL) is proposed to limit the fault current that occurs in power system, SFCL is a device that uses superconductors to instantaneously limit or reduce unanticipated electrical surges that may occur on utility distribution and transmission networks. Due to the difficulty in power network reinforcement and the interconnection of more distributed generations, fault current level has become a serious problem in transmission and distribution system operations. The utilization of fault current limiters (FCLs) in power system provides an effective way to suppress fault currents and result in considerable saving in the investment of high capacity circuit breakers is felt. In this work, a resistive type SFCL model was implemented by integrating Simulink and Sim Power System blocks in Matlab. The designed SFCL model could be easily utilized for determining an impedance level of SFCL according to the fault-current-limitation requirements of various kinds of the DC system. In this paper SFCL in dc systems implemented, and it is used in motor drive to reduce the fault current.
منابع مشابه
Influence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملThe Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System
In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...
متن کاملA New Method to Enhance the Low Voltage Ride Through Capability of Doubly Fed Induction Generator Using Resistive Type Superconducting Fault Current Limiter
In the event of voltage sag at the nearing of a wind park, severe currents may pass through the power electronic devices of the Doubly Fed Induction Generators (DFIGs). Hence, according to the Low Voltage Ride Through (LVRT) requirements, the wind parks are allowed to disconnect from the network after a certain time. Therefore, to avoid such actions, the LVRT requirement of wind parks is consid...
متن کاملStudy of Superconducting Fault Current Limiter Device in a AC Railway System
Development of the electric networks led to more interconnection in this system, therefore high level of short circuit faults flows in the networks. Many destructive damages such as instability, insulation problems and voltage mitigation can highly play unwanted influences on the system’s equipment. Using appropriate protection devices like high voltage fuses, fast switches, and such devices...
متن کاملDecreasing Distribution Generation Effects on Grid Short Circuit Level Using Superconducting Fault Current Limiter Through Updating Relays Set-Points
Power system protection at transmission and distribution levels based on overcurrent relays is essential based on their properties such as detection, stability, high speed, backup and error correction accuracy. Since distributed generation sources are connected to the power grid, they not only increase the short circuit level of the grid, but also disrupt the set point of main and backup relays...
متن کامل