Increase in mucociliary clearance in normal man induced by oral high frequency oscillation.

نویسندگان

  • R J George
  • M A Johnson
  • D Pavia
  • J E Agnew
  • S W Clarke
  • D M Geddes
چکیده

Data on the effect on mucociliary clearance of oral high frequency oscillation is conflicting. By means of a technique to superimpose high frequency oscillation on tidal breathing, changes in mucociliary clearance during high frequency oscillation were studied in seven normal non-smokers by monitoring the clearance of inhaled radiolabelled aerosol from the lungs. After inhalation of 5 microns technetium 99m labelled particles under controlled conditions, whole lung clearance was monitored by scintillation counters half hourly for six hours with a final count at 24 hours, from which tracheobronchial deposition and clearance could be calculated. Control and high frequency oscillation studies were performed on separate days in random order. Oral high frequency oscillation was applied by a bass loudspeaker through a mouthpiece to superimpose sinewave oscillations (RMS input pressure 1.2 cm H2O, mean pressure zero) on normal breaths. On high frequency oscillation days 30 minutes of oscillation alternated with 30 min of rest. Between 3 and 4.5 hours mucociliary clearance with high frequency oscillation exceeded control by about 10% (p less than 0.05). The mean time taken to eliminate 90% of deposited radioaerosol from the tracheobronchial tree fell from 4 hours 50 minutes (range 1 h 52 min-6 h 50 min) during control to 3 hours 43 minutes (range 2 hr 28 min-5 hr 54 min) during the high frequency oscillation run (p less than 0.05). Possibly this comfortable, simple technique would be of therapeutic benefit to patients with chronic sputum retention and merits further investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physiotherapy for airway clearance in adults.

Techniques for augmenting, when necessary, the normal mucociliary and cough clearance mechanisms of the lungs are not new, but, in more recent years, techniques have been developed which are effective, comfortable and can be used independent of an assistant in the majority of adolescents and adults. Postural drainage with chest clapping and chest shaking has, in most parts of the world, been re...

متن کامل

Nasal mucociliary clearance and ciliary beat frequency in cystic fibrosis compared with sinusitis and bronchiectasis.

Nasal ciliary function and mucociliary clearance were studied in patients with cystic fibrosis and in three control groups. Ciliary beat frequency and nasal clearance time were measured in groups of 10 subjects with cystic fibrosis, sinusitis and bronchiectasis and age and sex-matched control subjects. Ciliary beat frequency was also measured in normal subjects matched as bronchiectasis control...

متن کامل

Beat frequency of cilia from sites of purulent infection.

Mucociliary clearance depends on the interaction between cilia and mucus; it is delayed in the presence of purulent secretions. Nasal mucociliary clearance was examined by the saccharin method and nasal ciliary beat frequency by a photometric technique. Four groups were studied: normal controls, patients with bronchiectasis without nasal symptoms, patients with chronic mucopurulent sinusitis al...

متن کامل

Effect of myrtol standardized and other substances on the respiratory tract: ciliary beat frequency and mucociliary clearance as parameters.

INTRODUCTION Myrtol standardized is a phytomedicine obtained by distillation, consisting of many constituents. In vitro and in vivo, the major monterpenes, d-limonene, 1,8-cineole, and alpha-pinene, are used as biological marker substances. Myrtol standardized has secretolytic, secretomotor, and mucolytic effects in addition to anti-inflammatory and antioxidative actions. The aim of the study w...

متن کامل

Smoking Is Associated with Shortened Airway Cilia

BACKGROUND Whereas cilia damage and reduced cilia beat frequency have been implicated as causative of reduced mucociliary clearance in smokers, theoretically mucociliary clearance could also be affected by cilia length. Based on models of mucociliary clearance predicting that cilia length must exceed the 6-7 microm airway surface fluid depth to generate force in the mucus layer, we hypothesized...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 40 6  شماره 

صفحات  -

تاریخ انتشار 1985