Evaluation of applicability of the Sartorius Airport MD8 sampler for detection of Bacillus endospores in indoor air
نویسندگان
چکیده
This study was designed to evaluate the measuring range and lowest limit of detection of Bacillus endospores in the ambient room air when the Sartorius MD8 sampler, and two different culture methods for bacterial enumeration were used. Different concentrations of bioaerosol were generated inside the test chamber filled with either the high-efficiency particulate air (HEPA)-filtered air or with the ambient room air. The detection of endospores in the HEPA-filtered air was achievable: (1) when they were aerosolized at a concentration above 7.56 × 10(3) CFU/m(3) and analyzed with spread plate method, and (2) when they were aerosolized at a concentration above 4.00 × 10(2) CFU/m(3) and analyzed with pour plate method. The detection of endospores in the ambient room air was possible: (1) when they were aerosolized at a concentration above 9.1 × 10(3) CFU/m(3) and analyzed with spread plate method, and (2) when they were aerosolized at a concentration above 5.6 × 10(2) CFU/m(3) and analyzed with pour plate method. The microorganisms present in the ambient room air interfere with precise quantification of Bacillus endospores when their concentration is relatively low. The results of this study may be helpful in critical assessment of the results obtained from monitoring the air for bacterial endospores.
منابع مشابه
Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review
Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...
متن کاملAssessment of air pollution in exercise centers and health risks
Background: In recent years, Tehran has faced major problems with air pollution for many reasons, and this issue has become a critical point in most of the days. However, less attention has been paid to the indoor air pollutants in exercise centers and their possible health effects. In this research, it was tried to briefly describe the characteristics and chemical composition of the aerosols p...
متن کاملبررسی مقایسهای غلظت ذرات معلق در هوای داخل با هوای آزاد خارج بیمارستان دنا شیراز
Abstract Introduction & Purpose: Indoor air quality, particularly in health care facility, is important. One of the most important factors affect the air quality is aerosols due to carrying microorganisms and deposit in the respiratory tract. Therefore, the purpose of this study was to measure the concentration of suspended particles in outdoor and indoor of Dena hospital and determine the re...
متن کاملEvaluation of cooking emitted particulate matter concentration and workers cancer risk assessment in the sari fast-food shops
Introduction: One of the harmful pollutants in the indoor environments is particulate matters. Particles smaller than 2.5 micrometer in diameter that are suspend in the industrial environments air are the most deleterious dusts which can cause lung disease and cancer. In present study PM2.5 concentration in the fast-food shops air and its cancer risk for shop workers were assessed. Material ...
متن کاملEnglish Needs Analysis of Iran Air Airport Services Personnel at Isfahan Airport
Although English language plays an important role in the job of aviation personnel, language needs of these employees have been taken for granted. This study aimed at investigating the extent to which English is used by the employees at Iran Air airport services at Isfahan Airport, the required level of basic language skills in performing their jobs effectively, and the employees’ attitude towa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 185 شماره
صفحات -
تاریخ انتشار 2013