Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants
نویسندگان
چکیده
BACKGROUND Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. METHODS A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. RESULTS The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. CONCLUSIONS It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.
منابع مشابه
In-vitro wear measurement of total knee replacement using tibial polyethylene inserts in combination with ceramic and metallic femoral components under abrasive three body wear conditions
INTRODUCTION: Due to increased life expectancy at human population the amount of osteoarthritis of the knee joint will increase. The total knee replacement (TKR) is often the only way to achieve analgesia, to establish the joint function and to correct joint deformation. TKR reached a high grade of quality and safety and has become an often used surgical procedure [1]. TKR most often fail due t...
متن کاملWear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and Martens hardness.
OBJECTIVES This study determined the two-body wear and toothbrushing wear parameters, including gloss and roughness measurements and additionally Martens hardness, of nine aesthetic CAD/CAM materials, one direct resin-based nanocomposite plus that of human enamel as a control group. MATERIALS AND METHODS Two-body wear was investigated in a computer-controlled chewing simulator (1.2 million lo...
متن کاملAssessment of non-contacting optical methods to measure wear and surface roughness in ceramic total disc replacements.
This study presents a method for measuring the low volumetric wear expected in ceramic total disc replacements, which can be used to replace intervertebral discs in the spine, using non-contacting optical methods. Alumina-on-alumina ball-on-disc tests were conducted with test conditions approximating those of cervical (neck region of the spine) total disc replacement wear tests. The samples wer...
متن کاملWear Loss Evaluation of Silicon Nitride-Hexagonal Boron Nitride Composite using Taguchi Method
Biomaterials in body environment are expected to work satisfactorily, where the pH value of body fluid varies from 1 to 9. Friction, wear, and lubrication of artificial joints are an important consideration to optimise the performance of these man-made joints to improve its function and life. The first metal-on-metal (CoCr-CoCr) total hip replacement (THR) was unsatisfactory because of high fri...
متن کاملThe Effectiveness of Ceramic Wiper Tool in Turning of Monel K500
In this study, turning operation of Monel K500 copper-nickel super-alloy was evaluated. Ceramic cutting tools with two different cutting noses (conventional and wiper) were utilized. At first, the experimental tests were designed by using central composite design method. After implementation of the tests, the statistical models for output data (surface roughness, cutting force, and flank wear) ...
متن کامل