Inflammatory foreign body reaction caused by resorbable materials used for orbital fractures repair

نویسندگان

  • Jie He
  • Wodong Shi
چکیده

RATIONALE Resorbable materials have been recommended for orbital fractures repair. Many literatures reported the advantages of resorbable materials in clinical applications, but few reports about complications. PATIENT CONCERNS In this study, we encountered a 14-year-old boy treated for the orbital fracture by using resorbable plate, in whom inflammatory foreign body reaction was detected. In addition, this patient had repeated history of skin allergy and upper respiratory tract infection. DIAGNOSES Intraoperative observation showed that the resorbable material near the orbital rim was covered by granulation and inflammatory tissues, without purulent secretions. The histological examination revealed inflammatory foreign body reaction to the resorbable plate. INTERVENTIONS Debridement was taken to remove the mass on the left lower eyelid. At the outpatient examination, a small amount of granulation tissue was found at the incision. Then, secondary surgery for exploration and removal of the resorbable material was carried, 9 months after the first surgery. OUTCOMES One month after the surgery, the skin retraction, ectropion, and edema gradually improved. LESSONS Inadequate degradation of resorbable materials and patient's medical history of allergies may cause an inflammatory foreign body reaction. Therefore, it is prudent to choose resorbable materials for patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomaterials for orbital fractures repair

The unique and complex anatomy of the orbit requires significant contouring of the implants to restore the proper anatomy. Fractures of the orbital region have an incidence of 10-25% from the total facial fractures and the most common age group was the third decade of life. The majority of cases required reconstruction of the orbital floor to support the globe position and restore the shape of ...

متن کامل

Use of copolymer polylactic and polyglycolic acid resorbable plates in repair of orbital floor fractures.

The fractures of the orbital floor are common after craniofacial trauma. Repair with resorbable plates is a viable reconstructive option; however, there are few reports in the literature. This study describes our experience using copolymer polylactic and polyglycolic acid (PLLA/PGA) orbital reconstruction plates (LactoSorb, Lorenz Surgical, Jacksonville, FL) in 29 cases of the orbital floor fra...

متن کامل

Use of resorbable implants for mandibular fixation: a systematic review.

Titanium plating is recognized as the criterion standard for the treatment of mandibular fractures and osteotomies. Use of resorbable implants is well documented in the literature for a range of craniofacial fractures. However, no clear review exists of the use of resorbable implants on the mandible. In this systematic review, we searched MEDLINE/PubMed and the Cochrane Database for studies of ...

متن کامل

Delayed onset porous polyethylene implant-related inflammation after orbital blowout fracture repair: four case reports

BACKGROUND Porous polyethylene implants are commonly used in orbital blowout fracture repair because of purported biocompatibility, durability, and low frequency of complications. Delayed inflammation related to porous polyethylene sheet implants is very rare and no case series of this condition have been reported. CASE PRESENTATION This is a retrospective review of clinical presentations, ra...

متن کامل

Repair of orbital floor fractures using bioresorbable poly-L/DL-lactide plates.

OBJECTIVE To assess the long-term clinical and radiologic findings after insertion of a bioresorbable polylactide plates P(L/DL)LA 70/30 implant (PolyMax) in the repair of orbital floor and wall defects, with special focus on stability and clinical signs of foreign-body reaction. METHODS Forty-six patients who had orbital blowout fractures with at least 1.5-cm(2) bone defects in 1 or 2 walls ...

متن کامل