Does help structures play a role in reducing the variation of dwell time in IPSA planning for gynaecological brachytherapy application?
نویسندگان
چکیده
PURPOSE To report our experience of dosimetric comparison of IPSA and manual plans, with a focus on the use of help structures (HS) during optimization. MATERIAL AND METHODS 33 patients who underwent MR image-based HDR intracavitary-brachytherapy for cervix cancer based on GYN-ESTRO recommendations were selected for evaluation. Tandem/ovoid (T/O) and Vienna applicators were used. HS of diameter of 5 mm were drawn around the tandem/needles/ovoid and ring. Three plans were generated: manual optimized plan (MOPT), IPSA without help structures (IPSA_woHS) and IPSA with help structures (IPSA_wHS). Dose-volume parameters and the loading pattern were evaluated. RESULTS For T/O, the use of HS did not make significant impact in the dose-volume parameters and in the loading of tandem and ovoids, however steep variation was found in the individual dwell time. In case of Vienna applicator, inclusion of HS in the optimization made a significant impact in loading of needles. The percentage ratio of total time of needles to the tandem (T(N/T%)) was found to be 14±2.5, 53±9, 22±6 for MOPT, IPSA_woHS and IPSA_wHS, respectively, which implies that in IPSA_woHS the dwell time in needles were half of the dwell time in the tandem, while in MOPT the needles were loaded only in 14%, and in IPSA_wHS it was 22% of the dwell time of tandem. Inclusion of HS in the optimization has reduced the contribution of dwell time of needle in IPSA_wHS. The individual variation of dwell time was also reduced in IPSA_wHS, however drawing of HS is a time consuming procedure and may not be practical for a routine practice. CONCLUSION The role of HS was evaluated for IPSA for T/O and Vienna-applicator, the use of HS may be beneficial in case of combined intracavitary - interstitial approach.
منابع مشابه
Comparison of Oncentra® Brachy IPSA and graphical optimisation techniques: a case study of HDR brachytherapy head and neck and prostate plans
There are a number of different dwell positions and time optimisation options available in the Oncentra® Brachy (Elekta Brachytherapy Solutions, Veenendaal, The Netherlands) brachytherapy treatment planning system. The purpose of this case study was to compare graphical (GRO) and inverse planning by simulated annealing (IPSA) optimisation techniques for interstitial head and neck (HN) and prost...
متن کامل2D linear array device as a quality assurance tool in brachytherapy applications
Background: External beam radiotherapy and brachytherapy plays a vital role in the management of cancer cervix. High dose rate brachytherapy is being presently used worldwide for the brachytherapy applications. At present, 2-Dimensional linear array detectors are the most common QA tool used for pretreatment patient specific quality assurance in external beam radiotherapy alon...
متن کاملRobustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements
PURPOSE Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more ...
متن کاملIndependent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader
Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and ...
متن کاملOptimization of HDR brachytherapy dose distributions using linear programming with penalty costs.
Prostate cancer is increasingly treated with high-dose-rate (HDR) brachytherapy, a type of radiotherapy in which a radioactive source is guided through catheters temporarily implanted in the prostate. Clinicians must set dwell times for the source inside the catheters so the resulting dose distribution minimizes deviation from dose prescriptions that conform to patient-specific anatomy. The pri...
متن کامل