Complicated Holter tracing with an incidence of inappropriate mode switch due to sensing abnormalities in a patient with dual-chamber pacemaker.
نویسندگان
چکیده
24-hour Holter monitoring of a 59 year-old man with DDDR pacemaker (programmed mode: DDD) implanted for sick sinus syndrome with paroxysmal atrial fibrillation was performed one month after implantation, due to palpitations. Several episodes of rapid pacing of decreasing rate were detected. Intracardiac recording stored in the pacemaker memory had shown episodes of atrial lead oversensing, which led to the mode switch, resulting in DDIR mode. Signals which caused oversensing were not seen in Holter tracing.
منابع مشابه
Use of an Atrial Lead with Very Short Tip-To-Ring Spacing Avoids Oversensing of Far-Field R-Wave
OBJECTIVE The AVOID-FFS (Avoidance of Far-Field R-wave Sensing) study aimed to investigate whether an atrial lead with a very short tip-to-ring spacing without optimization of pacemaker settings shows equally low incidence of far-field R-wave sensing (FFS) when compared to a conventional atrial lead in combination with optimization of the programming. METHODS Patients receiving a dual chamber...
متن کاملDual chamber cardiac pacing in children: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker?
BACKGROUND Dual chamber pacemakers (single chamber pacing dual chamber sensing cardiac pacemaker (VDD) and dual chamber pacing and sensing cardiac pacemaker (DDD)) are being used frequently in children and adolescents. The aim of this study was to verify the safety and performance of the VDD and DDD pacing systems, and to evaluate the differences between two pacing modes with regard to atrial s...
متن کاملInitial experience with dual-sensor rate-responsive pacemakers in children.
The efficacy of a new single-chamber, rate-responsive pacemaker that utilizes information from two sensors, activity and stimulus to T wave, was evaluated in 15 children during a mean follow-up period of 10.3 +/- 3.3 months (range 5-16 months). There were 10 males and five females, with a mean age of 5.9 +/- 3.8 years (range 9 months-16 years). The indication for pacing was high grade atriovent...
متن کاملInappropriate mode switch consecutive to P-wave double counting.
We report a case of multiple inappropriate mode switches in a patient with a dual-chamber pacemaker, resulting from P-wave double counting due to a double potential on the atrial electrogram. The differential diagnosis of this rarely reported phenomenon is discussed.
متن کاملPacemaker lead endocarditis with hiccups (Kalayci)
Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiology journal
دوره 18 1 شماره
صفحات -
تاریخ انتشار 2011