Dynamic Electrochemical Measurement of Chloride Ions.

نویسندگان

  • Yawar Abbas
  • Derk B de Graaf
  • Wouter Olthuis
  • Albert van den Berg
چکیده

This protocol describes the dynamic measurement of chloride ions using the transition time of a silver silver chloride (Ag/AgCl) electrode. Silver silver chloride electrode is used extensively for potentiometric measurement of chloride ions concentration in electrolyte. In this measurement, long-term and continuous monitoring is limited due to the inherent drift and the requirement of a stable reference electrode. We utilized the chronopotentiometric approach to minimize drift and avoid the use of a conventional reference electrode. A galvanostatic pulse is applied to an Ag/AgCl electrode which initiates a faradic reaction depleting the Cl- ions near the electrode surface. The transition time, which is the time to completely deplete the ions near the electrode surface, is a function of the ion concentration, given by the Nernst equation. The square root of the transition time is in linear relation to the chloride ion concentration. Drift of the response over two weeks is negligible (59 µM/day) when measuring 1 mM [Cl-]using a current pulse of 10 Am(-2). This is a dynamic measurement where the moment of transition time determines the response and thus is independent of the absolute potential. Any metal wire can be used as a pseudo-reference electrode, making this approach feasible for long-term measurement inside concrete structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Chloride Ions Concentration on the Electrochemical Behavior of AISI 410 Stainless Steels in Simulated Concrete Pore Solution

The effect of chloride ions concentration on the electrochemical behavior of AISI 410 stainless steel in the simulated concrete pore (0.1 M NaOH + 0.1 M KOH) solution was investigated by various electrochemical methods such as Potentiodynamic polarization, Mott–Schottky analysis and electrochemical impedance spectroscopy (EIS). Potentiodynamic polarization curves revealed that increasing chlori...

متن کامل

Formaldehyde measurement based on its electrocatalytic oxidation by Ni-TiO2 nanoparticles/chitosan modified carbon paste electrode as an effective method

In this work, for the first time, a new and effective bulk modified carbon paste electrode (CPE) was prepared by TiO2 nanoparticles and chitosan and then Ni2+ ions were incorporated to this electrode by immersion of the modified electrode in nickel chloride solution. The values of electron transfer coefficient, charge-transfer rate constant and electrode surface coverage f...

متن کامل

Formaldehyde measurement based on its electrocatalytic oxidation by Ni-TiO2 nanoparticles/chitosan modified carbon paste electrode as an effective method

In this work, for the first time, a new and effective bulk modified carbon paste electrode (CPE) was prepared by TiO2 nanoparticles and chitosan and then Ni2+ ions were incorporated to this electrode by immersion of the modified electrode in nickel chloride solution. The values of electron transfer coefficient, charge-transfer rate constant and electrode surface coverage f...

متن کامل

PVA and EDTA grafted superparamagnetic Ni doped iron oxide nanoparticles prepared by constant current electrodeposition for biomedical applications

In this paper, a rapid and room temperature electrochemical method is introduced in preparationof Ni doped iron oxide nanoparticles (Ni-IONs) grafted with ethylenediaminetetraacetic acid (EDTA)and polyvinyl alcohol (PVA). EDTA/Ni-IONs and PVA/Ni-IONs samples were prepared through baseelectro-generation on the cathode surface from aqueous solution of iron(II) chloride, iron(III...

متن کامل

Fabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of visualized experiments : JoVE

دوره 108  شماره 

صفحات  -

تاریخ انتشار 2016