Measurement of macular pigment: Raman spectroscopy versus heterochromatic flicker photometry.

نویسندگان

  • Kumari Neelam
  • Nicholas O'Gorman
  • John Nolan
  • Orla O'Donovan
  • Hwee Bee Wong
  • Kah Guan Au Eong
  • Stephen Beatty
چکیده

PURPOSE There are several techniques for measuring macular pigment (MP) in vivo, of which Raman spectroscopy (RS) is a recently developed objective METHOD This study reports the reproducibility, test-retest variability, and validity of RS MP readings, by comparing them with heterochromatic flicker photometry (HFP). METHODS MP was measured with HFP and RS in 120 healthy subjects, and the latter technique was also used on two separate occasions in a sample of 20 subjects to investigate the intersessional variability of readings. Intrasessional reproducibility of RS MP measurements was also calculated. In addition, serum concentrations of lutein (L) and zeaxanthin (Z) were measured and correlated with both RS and HFP MP readings. RESULTS Mean (+/-SD) MP in the right eye was 0.279 +/- 0.145 and 0.319 +/- 0.155 with RS and HFP, respectively. The differences between corresponding MP readings taken on RS and HFP lay within the Bland-Altman 95% limits of agreement for the two instruments in 93.6% and 94.4% of cases in the right and left eyes, respectively. Intrasessional reproducibility of RS readings, expressed as the coefficient of variation, was 8.42% +/- 7.12%. Ninety-five percent of MP readings taken with RS on two separate occasions lay within the 95% limits of agreement for the two sessions. A positive, but insignificant, relationship was observed between RS and HFP MP readings and serum concentrations of L and Z (RS, P = 0.356; HFP, P = 0.540). CONCLUSIONS RS, an objective method of measuring MP levels in vivo, exhibits acceptable reproducibility and test-retest variability. The results demonstrated good correlation between RS and HFP measurements of MP, thus authenticating RS against a validated psychophysical technique of measuring MP. However, investigators should use only one of these instruments for the duration of any given study because of differences in the scientific rationale, and the factors that influence RS and HFP measurements of MP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Macular pigment measurement by heterochromatic flicker photometry in older subjects: the carotenoids and age-related eye disease study.

PURPOSE To develop a standardized protocol for measuring macular pigment optical density (MPOD) of experimentally naïve subjects by heterochromatic flicker photometry (HFP). METHODS MPOD in eyes of 54 women, age 50 and 79 years (mean, 66), was studied. The spatial profile of MPOD was measured in the right eye, and two spatial points were also measured in the left eye. Forty-eight of these ine...

متن کامل

Concordance of Macular Pigment Measurement Using Customized Heterochromatic Flicker Photometry and Fundus Autofluorescence in Age-Related Macular Degeneration.

PURPOSE We compared macular pigment (MP) measurements using customized heterochromatic flicker photometry (Macular Metrics Densitometer) and dual-wavelength fundus autofluorescence (Heidelberg Spectralis HRA + OCT MultiColor) in subjects with early age-related macular degeneration (AMD). METHODS Macular pigment was measured in 117 subjects with early AMD (age, 44-88 years) using the Densitome...

متن کامل

Macular Pigment Optical Density Measured by Heterochromatic Modulation Photometry

PURPOSE To psychophysically determine macular pigment optical density (MPOD) employing the heterochromatic modulation photometry (HMP) paradigm by estimating 460 nm absorption at central and peripheral retinal locations. METHODS For the HMP measurements, two lights (B: 460 nm and R: 660 nm) were presented in a test field and were modulated in counterphase at medium or high frequencies. The co...

متن کامل

Macular pigment density measured by autofluorescence spectrometry: comparison with reflectometry and heterochromatic flicker photometry.

We present a technique for estimating the density of the human macular pigment noninvasively that takes advantage of the autofluorescence of lipofuscin, which is normally present in the human retinal pigment epithelium. By measuring the intensity of fluorescence at 710 nm, where macular pigment has essentially zero absorption, and stimulating the fluorescence with two wavelengths, one well abso...

متن کامل

Clinical and Epidemiologic Research The Heritability of Macular Response to Supplemental Lutein and Zeaxanthin: A Classic Twin Study

METHODS. A total of 322 healthy female twin volunteers, aged 16–50 years (mean 40 6 8.7) was enrolled in a prospective, nonrandomized supplement study. Macular pigment optical density (MPOD) measurements using two techniques (2wavelength fundus autofluorescence [AF] and heterochromatic flicker photometry [HFP]), and serum concentrations of L and Z, were recorded at baseline, and at 3 and 6 mont...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 46 3  شماره 

صفحات  -

تاریخ انتشار 2005