Polymerization Stress Development in Dental Composites: Effect of Cavity Design Factor

نویسندگان

  • Joseph M. Antonucci
  • Anthony A. Giuseppetti
  • Justin N.R. O’Donnell
  • Gary E. Schumacher
  • Drago Skrtic
چکیده

The objective of the study was to assess the effect of the cavity design factor (C-factor) on polymerization stress development (PSD) in resin composites. An experimental resin (BT resin) was prepared, which contained 2,2-bis[p-(2'hydroxy-3'-methacryloxypropoxy)phenylene]propane (B) and triethylene glycol dimethacrylate (T) in 1:1 mass ratio, and an activator for visible light polymerization. Also an experimental composite with demonstrated remineralizing potential was formulated by inclusion into the BT resin of zirconia-hybridized amorphous calcium phosphate (ACP) filler at a mass fraction of 40 % (BT/ACP composite). A commercial glass-filled composite (TPH) was used as a control. To assess the effect of the test geometry on PSD, C-factor was systematically varied between 0.8 and 6.0 by varying the height of the cylindrical composite specimens. The measured PSD values obtained by cantilever beam tensometry for specimens with variable C-factors were normalized for mass to specimens with a C-factor of 1.33 (h=2.25 mm) as controls to give calculated PSD values. Degrees of vinyl conversions (DC) attained in the TPH control and in the experimental BT/ACP composites were measured by near-infrared spectroscopy. In both the TPH and BT/ACP composite series, PSDcalc increased with the increasing C-factor, confirming the hypothesis that the C-factor value influences PSD values. The higher PSDmeas and PSDcalc values for the experimental BT/ACP composite compared to the commercial TPH composite probably reflect differences in the type and mass of the resin and filler phases in the two types of composite. These differences also account for the observed variation (21 %) in DC attained in a BT/ACP composite 2 h after cure (69.5 %) and in the DC of the TPH composite (57.5 %) having the same C-factor. The cavity design factor seems to play a key role in influencing the PSD of bonded composites, but other factors such as composite mass and composition also must be considered for their effects on PSD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors involved in the development of polymerization shrinkage stress in resin-composites: a systematic review.

OBJECTIVES Polymerization shrinkage stress of resin-composite materials may have a negative impact on the clinical performance of bonded restorations. The purpose of this systematic review is to discuss the primary factors involved with polymerization shrinkage stress development. DATA According to the current literature, polymerization stress of resin composites is determined by their volume...

متن کامل

A Review of Silorane and Methacrylate Based Composites and Effective Factors on Microleakage of them

Introduction: An important disadvantage of current dental resin composites is their polymerization shrinkage and production of microleakage. This shrinkage can cause tooth sensitivity, marginal discoloration, and secondary caries. The objective of this study was to review the effective factors on microleakage of methacrylate and silorane composites and compare them with each other. This review...

متن کامل

Effect of layering methods, composite type, and flowable liner on the polymerization shrinkage stress of light cured composites.

OBJECTIVES The aim of this study was to investigate the effect of layering methods, flowable composite liner and use of low shrinkage silorane-based composite on the polymerization shrinkage stress of light cured composites. METHODS Aluminum blocks were used to prepare MOD cavities and divided into four groups. A universal hybrid methacrylate-based composite (Z250), a flowable composite (Z350...

متن کامل

Effect of Cavity Dimentions with the Same C-Factor on Micro Leakage of Composite Resin Cavities

Abstract Background and aim: Given the prevalence of microleakage in composites and their known complications and lack of reporting of the influence of cavity depth and diameter on the same c-factor on the microleakage of composite cavities, this study investigated the effect of microleakage on composite cavities in identical C Factors. Materials and Methods: In this experimental study on 40 ...

متن کامل

Alternatives in polymerization contraction stress management.

Polymerization contraction stress of dental composites is often associated with marginal and interfacial failures of bonded restorations. The magnitude of stress depends on composite composition (filler content and matrix composition) and its ability to flow before gelation, which is related to the cavity configuration and curing characteristics of the composite. This article reviews variations...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2009