Tissue characteristics at microthreaded implants: an experimental study in dogs.

نویسندگان

  • Ingemar Abrahamsson
  • Tord Berglundh
چکیده

PURPOSE The aim of the present study was to analyze bone tissue reactions at implants with and without a microthread configuration. MATERIALS AND METHODS In six beagle dogs, one test and two control implants were installed in one side of the mandible. While both implant types had a similar dimension and surface roughness, the test implants were designed with a microthread configuration in the marginal portion. Abutment connection was performed after 3 months. Another 3 months later, fixed partial dentures (FPDs) were cemented to the maxillary canine and premolars and FPDs were connected to the implants in the mandible. Ten months later, the animals were sacrificed and biopsies from each implant region were processed for histological analysis. Radiographs were obtained at implant placement after FPD connection and at the termination of the experiment. RESULTS The radiographic examination revealed that the marginal bone level was well preserved at both test and control implants during the entire 16-month period. The degree of bone-implant contact within the marginal portion of the implants was significantly higher at the test (microthread) implants (81.8%) than at the control implants (72.8%). CONCLUSIONS It was suggested that the microthread configuration offered improved conditions for osseointegration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peri-Implant Behavior of Sloped Shoulder Dental Implants Used for All-On-Four Protocols: An Histomorphometric Analysis in Dogs

The aim of this study was to evaluate the soft tissue thickness and marginal bone loss around dental implants with sloped micro-threaded shoulder (35° angle) in comparing with conventional design, inserted 35° degrees angulated in post extraction sockets and immediate loaded with temporary prosthesis simulating the all-on-four protocol. Materials and Methods: Six fox hound dogs received forty-e...

متن کامل

A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants

PURPOSE The marginal bone levels around implants following restoration are used as a reference for evaluating implant success and survival. Two design concepts that can reduce crestal bone resorption are the microthread and platform-switching concepts. The aims of this study were to analyze the placement of microthreaded and platform-switched implants and their short-term survival rate, as well...

متن کامل

Spontaneous progression of experimental peri-implantitis at implants with different surface characteristics: an experimental study in dogs.

AIM To analyse spontaneous progression of ligature-induced peri-implantitis at implants with different surface characteristics. MATERIAL AND METHODS Four implants with similar geometry and with two different surface characteristics (turned/TiUnite; Nobel Biocare AB) were placed pairwise in one side of the mandible in five dogs, 3 months after tooth extraction. Experimental peri-implantitis wa...

متن کامل

The Effect Of Restoration Type On Osseointegration of Dental Implants: A Histological Analysis In Dogs

  Background and Objective: The concept of immediate occlusal loading with dental implants offers several advantages. In this research, the effect of type of restoration on Osseointegration rate of dental implants was histologically evaluated. Materials and Methods: Three months prior to implantation, the lower premolar teeth of 15 dogs were extracted. Then, 3 to 4 Maestro™ implants were plac...

متن کامل

Marginal bone loss evaluation around immediate non-occlusal microthreaded implants placed in fresh extraction sockets in the maxilla: a 3-year study.

OBJECTIVE To evaluate marginal bone loss over 3 years around immediate microthreaded implants placed in the maxillary anterior/esthetic zone and immediately restored with single crowns. MATERIAL AND METHODS Seventy-one implants (with microthreads up to the platform--rough surface body and neck, internal connection and platform switching) were placed in fresh extraction sockets in the maxillar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical implant dentistry and related research

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 2006