Bilateral kidney preservation by volumetric-modulated arc therapy (RapidArc) compared to conventional radiation therapy (3D-CRT) in pancreatic and bile duct malignancies

نویسندگان

  • Sabine Vieillot
  • David Azria
  • Olivier Riou
  • Carmen Llacer Moscardo
  • Jean-Bernard Dubois
  • Norbert Aillères
  • Pascal Fenoglietto
چکیده

BACKGROUND To compare volumetric-modulated arc therapy plans with conventional radiation therapy (3D-CRT) plans in pancreatic and bile duct cancers, especially for bilateral kidney preservation. METHODS A dosimetric analysis was performed in 21 patients who had undergone radiotherapy for pancreatic or bile duct carcinoma at our institution. We compared 4-field 3D-CRT and 2 arcs RapidArc (RA) plans. The treatment plan was designed to deliver a dose of 50.4 Gy to the planning target volume (PTV) based on the gross disease in a 1.8 Gy daily fraction, 5 days a week. Planning objectives were 95% of the PTV receiving 95% of the prescribed dose and no more than 2% of the PTV receiving more than 107%. Dose-volume histograms (DVH) for the target volume and the organs at risk (right and left kidneys, bowel tract, liver and healthy tissue) were compared. Monitor units and delivery treatment time were also reported. RESULTS All plans achieved objectives, with 95% of the PTV receiving ≥ 95% of the dose (D95% for 3D-CRT = 48.9 Gy and for RA = 48.6 Gy). RapidArc was shown to be superior to 3D-CRT in terms of organ at risk sparing except for contralateral kidney: for bowel tract, the mean dose was reduced by RA compared to 3D-CRT (16.7 vs 20.8 Gy, p = 0.0001). Similar result was observed for homolateral kidney (mean dose of 4.7 Gy for RA vs 12.6 Gy for 3D-CRT, p < 0.0001), but 3D-CRT significantly reduced controlateral kidney dose with a mean dose of 1.8 Gy vs 3.9 Gy, p < 0.0007. Compared to 3D-CRT, mean MUs for each fraction was significantly increased with RapidArc: 207 vs 589, (p < 0.0001) but the treatment time was not significantly different (2 and 2.66 minutes, p = ns). CONCLUSION RapidArc allows significant dose reduction, in particular for homolateral kidney and bowel, while maintaining target coverage. This would have a promising impact on reducing toxicities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

متن کامل

Ipsilateral kidney sparing in treatment of pancreatic malignancies using volumetric-modulated arc therapy avoidance sectors.

Recent research has shown treating pancreatic cancer with volumetric-modulated arc therapy (VMAT) to be superior to either intensity-modulated radiation therapy or 3-dimensional conformal radiotherapy (3D-CRT), with respect to reducing normal tissue toxicity, monitor units, and treatment time. Furthermore, using avoidance sectors with RapidArc planning can further reduce normal tissue dose whil...

متن کامل

Simultaneous couch and gantry dynamic arc rotation (CG‐Darc) in the treatment of breast cancer with accelerated partial breast irradiation (APBI): a feasibility study

The purpose of this study was to compare the dosimetry of CG-Darc with three-dimensional conformal radiation therapy (3D CRT) and volumetric-modulated arc therapy (RapidArc) in the treatment of breast cancer with APBI. CG-Darc plans were generated using two tangential couch arcs combined with a simultaneous noncoplanar gantry arc. The dynamic couch arc was modeled by consecutive IMRT fields at ...

متن کامل

Dosimetric and clinical toxicity comparison of critical organ preservation with three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and RapidArc for the treatment of locally advanced cancer of the pancreatic head.

PURPOSE We compared dosimetry and clinical toxicity for 3-dimensional conformal radiotherapy (3D-crt), intensity-modulated radiotherapy (imrt), and RapidArc (Varian Medical Systems, Palo Alto, CA, U.S.A.) in locally advanced pancreatic cancer (lapcc). We hypothesized that the technique with better sparing of organs at risk (oars) and better target dose distributions could lead to decreased clin...

متن کامل

Performance evaluation of gated volumetric modulated arc therapy

Background: Aim of this study is to evaluate the accuracy of the gated volumetric modulated arc therapy (VMAT/RapidArc) using 2D planar dosimetry, DynaLog files and COMPASS 3D dosimetry system. Materials and Methods: Pre-treatment quality assurance of 10 gated VMAT plans was verified using 2D array and COMPASS 3D dosimetry system. Advantage of COMPASS over 2D planar is that it provides the clin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011