Energy calibration of the NaI(Tl) calorimeter of the SND detector using cosmic muons

نویسندگان

  • M. N. Achasov
  • A. D. Bukin
  • D. A. Bukin
  • V. P. Druzhinin
  • V. B. Golubev
  • V. N. Ivanchenko
  • S. V. Koshuba
  • S. I. Serednyakov
چکیده

The general purpose spherical nonmagnetic detector ( SND ) is now taking data at VEPP-2M ee collider in BINP ( Novosibirsk ) in the centre of mass energy range of 0.2 ÷ 1.4 GeV. The energy calibration of the NaI(Tl) calorimeter of the SND detector with cosmic muons is described. Using this method, the energy resolution of 5.5 % (σ) for 500 MeV photons was achieved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ar X iv : h ep - e x / 99 07 03 8 v 1 1 9 Ju l 1 99 9 Medium energy calorimetry at SND : techniques and performances on physics

SND (Spherical Neutral Detector) is a general purpose nonmagnetic detector, successfully operating at Novosibirsk VEPP-2M collider during last four years in the center of mass energy range from 400 MeV up to 1400 MeV. Its crucial part is a 3-layer, fine grained, spherical NaI(Tl) electromagnetic calorimeter consisted of 1632 individual counters. Here we present a detailed description of the cal...

متن کامل

Photon dosimetry based on selective data sampling for the NaI(TL) detector

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

متن کامل

Commissioning and Performance of the ATLAS Liquid Argon Calorimeters

The ATLAS liquid argon (LAr) calorimeter system consists of an electromagnetic barrel calorimeter and two end-caps with electromagnetic, hadronic and forward calorimeters. The construction of the full calorimeter system is completed since mid-2004. The detector has been operated with LAr at nominal high voltage and fully equipped with readout electronics. Online software, monitoring tools and o...

متن کامل

Measurement for the dose-rates of the cosmic-ray components on the ground.

In this study, we aimed to measure the directly ionizing component (muons and photons) and the indirectly ionizing component (neutrons) of the cosmic-ray spectra and evaluate their dose rate contribution to the total dose rate on a ground level in Japan. Measurements were carried out in Tohoku University, Japan, from October 2000. The pulse-height spectra of the cosmic-ray photons and muons wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998