Migration of carbon nanotubes from liquid phase to vapor phase in the refrigerant-based nanofluid pool boiling
نویسندگان
چکیده
The migration characteristics of carbon nanotubes from liquid phase to vapor phase in the refrigerant-based nanofluid pool boiling were investigated experimentally. Four types of carbon nanotubes with the outside diameters from 15 to 80 nm and the lengths from 1.5 to 10 μm were used in the experiments. The refrigerants include R113, R141b and n-pentane. The oil concentration is from 0 to 10 wt.%, the heat flux is from 10 to 100 kW·m-2, and the initial liquid-level height is from 1.3 to 3.4 cm. The experimental results indicate that the migration ratio of carbon nanotube increases with the increase of the outside diameter or the length of carbon nanotube. For the fixed type of carbon nanotube, the migration ratio decreases with the increase of the oil concentration or the heat flux, and increases with the increase of the initial liquid-level height. The migration ratio of carbon nanotube increases with the decrease of dynamic viscosity of refrigerant or the increase of liquid phase density of refrigerant. A model for predicting the migration ratio of carbon nanotubes in the refrigerant-based nanofluid pool boiling is proposed, and the predictions agree with 92% of the experimental data within a deviation of ±20%.
منابع مشابه
of Heat Transfer Technical Brief ool Boiling Experiments on ultiwalled Carbon Nanotube
n this study, two silicon wafer substrates were coated with vertially aligned multiwalled carbon nanotubes (MWCNT) “forests” nd were used for pool boiling studies. The MWCNT forests (9 nd 25 m in height) were synthesized on the silicon wafer subtrates using chemical vapor deposition (CVD) process. The subtrates were clamped on a cylindrical copper block with embeded cartridge heaters. The heat ...
متن کاملModeling of Upward Subcooled Flow Boiling of Refrigerant-113 in a Vertical Annulus
In this paper, a modified two-fluid model has been adopted to simulate the process of upward vertical subcooled flow boiling of refrigerant R-113 in a vertical annular channel at low pressure. The modified model considers temperature dependent properties and saturation temperature variation and was validated against a number of published low-pressure subcooled boiling experiments. The results s...
متن کاملExperimental Study for Investigating the Mechanism of Heat Transfer near the Critical Heat Flux in Nucleate Pool Boiling
Heat transfer coefficient in nucleate pool boiling near critical heat flux at least one orderhigher than the convectional heat transfer modes. In this paper, an experimental setup isdesigned and fabricated to investigate the mechanism of heat transfer from boiling surface tobulk liquid near critical heat flux. The images of pool boiling near the high heat flux regionreveals that the individual ...
متن کاملررسی تجربی افت فشار جریان جوششی مبرد R-134a در لولههای افقی
The pressure drop of refrigerant R-134a flow boiling inside a horizontal tube has been investigated experimentally. The test set-up which was used in this investigation is a well instrumented vapor compression refrigeration system. These instruments are thermocouples, flow meter, pressure gauges and the pressure drop measuring apparatus. This system consisted of three electrically heated evapor...
متن کاملAn Analytical Equation of State for Saturated Liquid Refrigerant Ternary Mixtures
In this work an analytical equation of state has been employed to calculate the PVT properties ofternary refrigerant mixtures. The theoretical EoS is that of Ihm, Song and Mason, which is based onstatistical-mechanical perturbation theory, and the two constants are enthalpy of vaporization ΔHvapand molar density ρnb, both at the normal boiling temperature. The following three temperaturedepende...