Structural characterization of unsaturated phosphatidylcholines using traveling wave ion mobility spectrometry.

نویسندگان

  • Hugh I Kim
  • Hyungjun Kim
  • Eric S Pang
  • Ernest K Ryu
  • Luther W Beegle
  • Joseph A Loo
  • William A Goddard
  • Isik Kanik
چکیده

A number of phosphatidylcholine (PC) cations spanning a mass range of 400-1000 Da are investigated using electrospray ionization mass spectrometry coupled with traveling wave ion mobility spectrometry (TWIMS). A high correlation between mass and mobility is demonstrated with saturated phosphatidylcholine cations in N(2). A significant deviation from this mass-mobility correlation line is observed for the unsaturated PC cation. We found that the double bond in the acyl chain causes a 5% reduction in drift time. The drift time is reduced at a rate of approximately 1% for each additional double bond. Theoretical collision cross sections of PC cations exhibit good agreement with experimentally evaluated values. Collision cross sections are determined using the recently derived relationship between mobility and drift time in TWIMS stacked ring ion guide (SRIG) and compared to estimated collision cross sections using an empiric calibration method. Computational analysis was performed using the modified trajectory (TJ) method with nonspherical N(2) molecules as the drift gas. The difference between estimated collision cross sections and theoretical collision cross sections of PC cations is related to the sensitivity of the PC cation collision cross sections to the details of the ion-neutral interactions. The origin of the observed correlation and deviation between mass and mobility of PC cations is discussed in terms of the structural rigidity of these molecules using molecular dynamic simulations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Collision Cross Section Calibrants for Structural Analysis of Lipids by Traveling Wave Ion Mobility-Mass Spectrometry

Collision cross section (CCS) measurement of lipids using traveling wave ion mobility-mass spectrometry (TWIM-MS) is of high interest to the lipidomics field. However, currently available calibrants for CCS measurement using TWIM are predominantly peptides that display quite different physical properties and gas-phase conformations from lipids, which could lead to large CCS calibration errors f...

متن کامل

Electrospray Ionization Traveling Wave Ion Mobility Spectrometry Mass Spectrometry for the Analysis of Plant Phenolics: An Approach for Separation of Regioisomers

Linus Pauling Institute, Oregon State University, Corvallis, OR 97331, USA Abstract The use of ion-mobility spectrometry (IMS) coupled to mass spectrometry (IMS–MS) for biomolecule analyses has steadily increased over the past two decades, and is now applied to both proteomic and metabolomic investigations. This chapter describes the application of traveling-wave ion-mobility spectrometry–mass ...

متن کامل

Carbohydrate and Glycoconjugate Analysis by Ion Mobility Mass Spectrometry: Opportunities and Challenges

Carbohydrates are characterized by a truly remarkable level of structural diversity which stands in accord with a corresponding functional diversity arguably unsurpassed by any other class of biomolecule. As metabolites, structural components, mediators of molecular interaction, and modifiers of other biomolecules, carbohydrates play central roles in numerous areas of biochemistry. Detailed mol...

متن کامل

Stable, trinuclear Zn(II)- and Cd(II)-metallocycles: TWIM-MS, photophysical properties, and nanofiber formation.

A series of trimeric, Zn(II)- and Cd(II)-metallocycles is reported. Structural characterization of the highly stable triangles was supported by traveling-wave ion mobility-mass spectrometry (TWIM-MS) and gradient tandem mass spectrometry (gMS(2)). Their unique photophysical properties and self-assembly to form nanofibers are also described.

متن کامل

Collision cross section calibrants for negative ion mode traveling wave ion mobility-mass spectrometry.

Unlike traditional drift-tube ion mobility-mass spectrometry, traveling-wave ion mobility-mass spectrometry typically requires calibration in order to generate collision cross section (CCS) values. Although this has received a significant amount of attention for positive-ion mode analysis, little attention has been paid for CCS calibration in negative ion mode. Here, we provide drift-tube CCS v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 81 20  شماره 

صفحات  -

تاریخ انتشار 2009