Transjugular liver biopsy: how good is it for accurate histological interpretation?

نویسندگان

  • E Cholongitas
  • A Quaglia
  • D Samonakis
  • M Senzolo
  • C Triantos
  • D Patch
  • G Leandro
  • A P Dhillon
  • A K Burroughs
چکیده

BACKGROUND A transjugular liver biopsy (TJLB) specimen is often smaller or more fragmented than a percutaneous liver biopsy (PLB) specimen. Recently, for PLB, the minimum requirements to evaluate chronic hepatitis have been set at 20-25 mm length and > or =11 complete portal tracts. AIM To evaluate and compare length of TJLB and PLB specimens, portal tract number, fragmentation and adequacy for histopathological diagnosis and staging. PATIENTS AND METHODS 326 consecutive TJLB specimens in 274 patients (109 who had undergone a transplantation), always using three passes (19-G Tru-cut) and 40 consecutive PLB specimens (15-G Menghini). RESULTS No technical failures occurred with the TJLB, and histological diagnosis was possible in 98.5%. The median (range) number of fragments was 5 (1-13) and the median total length was 22 (3-46) mm, with 65% of specimens > or =20 mm and 36% > or =25 mm; 60% of TJLB specimens were > or =28 mm long had > or =11 complete portal tracts. No difference in complete portal tract number or biopsy length was found between PLB and TJLB specimens. CONCLUSION A TJLB specimen with three passes is adequate for histological diagnosis, with 89% of specimens being either > or =15 mm or having > or =6 complete portal tracts. Although adequate sampling remains a limitation for staging and grading of chronic hepatitis, TJLB is comparable to PLB in this respect.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transjugular renal biopsy.

A novel technique to obtain renal biopsy specimens from patients in whom percutaneous renal biopsy is contraindicated is described. After adaptation of equipment used for transjugular liver biopsy, 50 such patients underwent transjugular renal biopsy: specimens of renal tissue were obtained from 44 patients, and glomeruli were found in 38 specimens. No major complications were observed and hist...

متن کامل

Transjugular liver biopsy using Tru-cut biopsy needle: KEM experience.

BACKGROUND AND AIM Transjugular liver biopsy is accepted procedure in patients in whom percutaneous liver biopsy is contraindicated. We report our experience with this procedure, its indications, efficacy and safety in Indian population over 5 years. MATERIAL & METHODS A retrospective study of 145 consecutive patients who had undergone transjugular liver biopsy from May 2002 to Nov. 2007 was ...

متن کامل

Transjugular liver biopsy. An update.

Transjugular liver biopsy was first reported in 1967. Since then, this technique has been broadly performed in many medical centers around the world. The number of its indications has increased, and by modifying the needles, the quality of the liver tissue sample has improved. The advantage of transjugular biopsy is that it can be performed in patients in whom the use of percutaneous biopsy is ...

متن کامل

Validation of AshTest as a Non-Invasive Alternative to Transjugular Liver Biopsy in Patients with Suspected Severe Acute Alcoholic Hepatitis

BACKGROUND/AIMS According to guidelines, the histological diagnosis of severe alcoholic steatohepatitis (ASH) can require liver biopsy if a specific treatment is needed. The blood test AshTest (BioPredictive, Paris, France) has been initially validated for the non-invasive diagnosis of ASH in a large population of heavy drinkers. The aim was to validate the AshTest accuracy in the specific cont...

متن کامل

Transjugular liver biopsy: a comparison of aspiration and trucut techniques.

The results of 67 transjugular liver biopsies are described. Two failures were encountered due to inability to pass the needle into acutely angulated hepatic veins. Thirty-four patients underwent a liver aspiration biopsy using a Colapinto needle, while the remainder were biopsied using a trucut needle. The success rate with the Colapinto needle was 68% and with the trucut model, 97%. Capsular ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Gut

دوره 55 12  شماره 

صفحات  -

تاریخ انتشار 2006