Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth
نویسندگان
چکیده
BACKGROUND The teeth with undiagnosed vertical root fractures (VRFs) are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. OBJECTIVES This study aimed to assess the use of different voxel resolutions of two different cone beam computerized tomography (CBCT) units in the detection VRFs in vitro. MATERIALS AND METHODS The study material comprised 74 extracted human mandibular single rooted premolar teeth without root fractures that had not undergone any root-canal treatment. Images were obtained by two different CBCT units. Four image sets were obtained as follows: 1) 3D Accuitomo 170, 4 × 4 cm field of view (FOV) (0.080 mm(3)); 2) 3D Accuitomo 170. 6 × 6 cm FOV (0.125 mm(3)); 3) NewTom 3G, 6˝ (0.16 mm(3)) and 4) NewTom 3G, 9˝ FOV (0.25 mm(3)). Kappa coefficients were calculated to assess both intra- and inter-observer agreements for each image set. RESULTS No significant differences were found among observers or voxel sizes, with high average Z (Az) results being reported for all groups. Both intra- and inter-observer agreement values were relatively better for 3D Accuitomo 170 images than the images from NewTom 3G. The highest Az and kappa values were obtained with 3D Accuitomo 170, 4 × 4 cm FOV (0.080 mm(3)) images. CONCLUSION No significant differences were found among observers or voxel sizes, with high Az results reported for all groups.
منابع مشابه
Diagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts
Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...
متن کاملComparing Fracture Resistance of Endodontically Treated Teeth Using Different Preparation-Obturation Combinations
Background:One of the main reasons for extraction of endodontically treated teeth is vertical root fracture (VRF). Some factors such as root canal treatment are involved in vertical root fracture because of their potential to weaken the tooth structure. Therefore, this study aimed to investigate the effect of combining different obturation materials and rotary systems on the fr...
متن کاملDetection of vertical root fractures by using cone beam computed tomography with variable voxel sizes in an in vitro model.
INTRODUCTION The aim of this study was to compare the diagnostic accuracy of cone beam computed tomography (CBCT) scans with different voxel resolutions in the detection of simulated vertical root fracture (VRF). METHODS Sixty teeth, 30 with root fractures and 30 without, were examined through i-CAT tomography at 4 different voxel resolutions (0.125, 0.2, 0.3, 0.4 mm). Three observers scored ...
متن کاملAccuracy comparison of CBCT scan and radiography with two different horzental angle in vertical root fracture detection of endodontically treated teeth
Background and Aims: Accurate diagnosis of vertical root fracture (VRF) is a fundamental importance in endodontics. Because of poor prognosis of VRF, digital radiographs with two horizontal angles have limitations in VRF detection. Also, Gutta-percha can produce artifacts that impair CBCT scan accuracy. The aim of this study was to compare accuracy of CBCT and digital radiography system in vert...
متن کاملComparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha
Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2015