Low-flow active and passive sampling of VOCs using thermal desorption tubes: theory and application at an offset printing facility.
نویسندگان
چکیده
While air sampling techniques using adsorbent-based collection, thermal desorption and chromatographic analysis have found a niche in ambient air sampling, occupational applications have been more limited. This paper evaluates the use of thermal desorption techniques for low flow active and passive sampling configurations which allow conveniently long duration sampling in occupational settings and other high concentration environments. The use of an orifice enables flows as low as 0.5 ml min(-1) and sampling periods up to several days without significant biases. A model is used to predict sampling rates of a passive sampler encompassing an orifice, a void space, glass wool, and the adsorbent. Laboratory and field tests conducted at a commercial offset printing facility, which contained a variety of volatile organic compounds (primarily aromatic but also a few chlorinated and terpene compounds at levels from 1 to 67,000 microg m(-3)), are used to evaluate the approach. Tenax GR and Carbosieve SIII, both singly and together, were employed as adsorbents. Side-by-side tests comparing high flow, low flow and passive samplers show excellent agreement and high linearity (r = 0.95) for concentrations spanning nearly five orders of magnitude. Active samplers were tested at flows as low as 0.5 ml min(-1), compared to typical flows up to 40 ml min(-1). Passive samplers demonstrated a linear range and agreement with predictions for adsorbate loadings from approximately 1 ng to nearly 10 microg. Using a chemical mass balance receptor model, concentrations in the facility were apportioned to solvents, inks and other indoor and outdoor sources. Overall, the use of low flow active and passive sampling approaches employing thermal desorption techniques provides good performance and tremendous flexibility that facilitates use in many applications, including workplace settings.
منابع مشابه
Comparison between Thermal Desorption Tubes and Stainless Steel Canisters Used for Measuring Volatile Organic Compounds in Petrochemical Factories.
OBJECTIVE The purpose of this study was to compare thermal desorption tubes and stainless steel canisters for measuring volatile organic compounds (VOCs) emitted from petrochemical factories. METHODS Twelve petrochemical factories in the Mailiao Industrial Complex were recruited for conducting the measurements of VOCs. Thermal desorption tubes and 6-l specially prepared stainless steel canist...
متن کاملOptimisation of sampling parameters for standardised exhaled breath sampling.
The lack of standardisation of breath sampling is a major contributing factor to the poor repeatability of results and hence represents a barrier to the adoption of breath tests in clinical practice. On-line and bag breath sampling have advantages but do not suit multicentre clinical studies whereas storage and robust transport are essential for the conduct of wide-scale studies. Several device...
متن کاملبررسی غلظت ترکیبات آلی فرار و گازهای آلاینده در مراکز چاپ و تکثیر شهر خرم آباد در سال 1394
Background : Given the large amount of gaseous and aerosol pollutants produced by the printing press industry, the indoor and outdoor air quality of such centers in Khorramabad, Iran was assessed. Methods and Materials: In a descriptive study, five gaseous pollutants from among criteria air pollutants (CO, NO, NO2, SO2, O3) and volatile organic compounds (VOCs) were measured. Overall, 360 sa...
متن کاملPassive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types.
This article describes laboratory testing of four passive diffusive samplers for assessing indoor air concentrations of volatile organic compounds (VOCs), including SKC Ultra II, Radiello®, Waterloo Membrane Sampler (WMS) and Automated Thermal Desorption (ATD) tubes with two different sorbents (Tenax TA and Carbopack B). The testing included 10 VOCs (including chlorinated ethenes, ethanes, and ...
متن کاملVOC level control by ventilation improvement of Flexography printing room using CFD modeling
Using Computational Fluid Dynamics (CFD) technique, the dispersion contours and the exposure rate of Flexographic printing workers to VOCs in a printing department is evaluated. Firstly, VOCs distribution is determined in the printing room due to the existing ventilation system. Through next steps, 4 scenarios for lowering VOCs concentration and its exposure rate to workers are analyzed. Concen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of environmental monitoring : JEM
دوره 4 3 شماره
صفحات -