Postoperative Pharyngolaryngeal Adverse Events with Laryngeal Mask Airway (LMA Supreme) in Laparoscopic Surgical Procedures with Cuff Pressure Limiting 25 cmH2O: Prospective, Blind, and Randomised Study

نویسندگان

  • Joo-Eun Kang
  • Chung-Sik Oh
  • Jae Won Choi
  • Il Soon Son
  • Seong-Hyop Kim
چکیده

To reduce the incidence of postoperative pharyngolaryngeal adverse events, laryngeal mask airway (LMA) manufacturers recommend maximum cuff pressures not exceeding 60 cmH₂O. We performed a prospective randomised study, comparing efficacy and adverse events among patients undergoing laparoscopic surgical procedures who were allocated randomly into low (limiting 25 cmH₂O, L group) and high (at 60 cmH₂O, H group) LMA cuff pressure groups with LMA Supreme. Postoperative pharyngolaryngeal adverse events were evaluated at discharge from postanaesthetic care unit (PACU) (postoperative day 1, POD 1) and 24 hours after discharge from PACU (postoperative day 2, POD 2). All patients were well tolerated with LMA without ventilation failure. Before pneumoperitoneum, cuff volume and pressure and oropharyngeal leak pressure (OLP) showed significant differences. Postoperative sore throat at POD 2 (3 versus 12 patients) and postoperative dysphagia at POD 1 and POD 2 (0 versus 4 patients at POD 1; 0 versus 4 patients at POD 2) were significantly lower in L group, compared with H group. In conclusion, LMA with cuff pressure limiting 25 cmH₂O allowed both efficacy of airway management and lower incidence of postoperative adverse events in laparoscopic surgical procedures. This clinical trial is registered with KCT0000334.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of manometry for laryngeal mask airway reduces postoperative pharyngolaryngeal adverse events: a prospective, randomized trial.

BACKGROUND Adverse events such as pharyngolaryngeal complications are indicators of quality patient care. Use of manometry to limit the laryngeal mask airway (LMA) intracuff pressure is not currently a routine practice. This double-blind randomized trial compared pharyngolaryngeal complications in patients managed with manometers to limit the LMA intracuff pressure (<44 mmHg) with patients unde...

متن کامل

Safety and efficacy of laryngeal mask airway Supreme versus laryngeal mask airway ProSeal: a randomized controlled trial.

BACKGROUND AND OBJECTIVE The Supreme laryngeal mask airway (LMA) is a new single-use polyvinyl chloride supraglottic device that combines the functionality of the ProSeal and Fastrach airways. High oropharyngeal leak pressures are important as they indicate airway protection, feasibility of positive pressure ventilation and likelihood of successful LMA placement. The oropharyngeal leak pressure...

متن کامل

Comparisons of clinical performance of guardian laryngeal mask with laryngeal mask airway ProSeal

BACKGROUND The Guardian Laryngeal Mask Airway (G-LMA) is a new silicone-based single-use extraglottic device with the drainage port and a cuff pilot valve with pressure indicator. The aim of this study is to compare the clinical performance of this laryngeal mask airway with ProSeal laryngeal mask airway (P-LMA). METHODS In this prospective randomized study, we included adult patients with AS...

متن کامل

Comparison of Supreme Laryngeal Mask Airway and ProSeal Laryngeal Mask Airway during Cholecystectomy.

OBJECTIVE This study compared the safety and efficacy of the Supreme Laryngeal Mask Airway (S-LMA) with that of the ProSeal-LMA (P-LMA) in laparoscopic cholecystectomy. MATERIAL AND METHODS Sixty adults were randomly allocated. Following anaesthesia induction, experienced LMA users inserted the airway devices. RESULTS Oropharyngeal leak pressure was similar in groups (S-LMA, 27.8±2.9 cmH2O;...

متن کامل

An implementation program targeted at non-physician, anaesthesia assistants improves the quality of laryngeal mask anaesthesia

The laryngeal mask airway (LMA) is used to facilitate adequate ventilation in the majority of procedures requiring general anaesthesia in the UK. Excessive LMA cuff pressure and/or volume, generated by injection of air to form an adequate seal within the upper airway, has been associated with pharyngolaryngeal morbidity, an indicator of quality in anaesthetic practice. However, measurement of L...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014