Trace-level determination of 1,4-dioxane in water by isotopic dilution GC and GC-MS.
نویسندگان
چکیده
The volatile and polar solvent 1,4-dioxane has recently been reported as a contaminant of ground and surface waters, establishing the need to determine this substance in drinking water. This investigation established that 1,4-dioxane can be determined in water by various techniques including direct aqueous injection (DAI) gas chromatography (GC) and purge and trap GC-mass spectrometry (MS). Purge and trap GC-MS is limited by 1,4-dioxane's poor purge efficiency, resulting in detection limits up to 100 times greater than the efficiently purged volatile organic compounds. To attain the sensitivity required for drinking water monitoring, a method based on continuous liquid-liquid extraction with dichloromethane was developed. Isotope dilution was more accurate and reproducible than quantification with external standards, and the improvement in precision led to a lower method detection limit, 0.2 microgram L-1, using a quadrupole ion trap instrument in the electron ionization mode. Isotope dilution accuracy approached 100% in ppb determinations. Isotopic dilution quantification was also possible using a non-selective GC detector owing to the high efficiency of capillary GC columns that resolve the deuterium-labeled solvent from the natural isotopes.
منابع مشابه
Combined Determination of 1,4-Dioxane and Nitrosamine Contaminants in Drinking Water Using SPE and CSR-LVSI GC-MS
Global concern over the carcinogenic potential of 1,4-dioxane and several nitrosamines has resulted in increased interest in the development of more efficient testing methods for these contaminants in drinking waters. In the U.S., the current methodologies recommended for the analysis of 1,4-dioxane and nitrosamines in drinking waters are Environmental Protection Agency (EPA) Methods 522 and 52...
متن کاملCombined Determination of 1,4-Dioxane and Nitrosamine Contaminants in Drinking Water Using a Single SPE Cartridge and Concurrent Solvent Recondensation– Large Volume Splitless Injection (CSR-LVSI) With EI GC-MS
Global concern over the carcinogenic potential of 1,4-dioxane and several nitrosamines has resulted in increased interest in the development of more e" cient testing methods for these contaminants in drinking waters. In the U.S., the current methodologies recommended for the analysis of 1,4-dioxane and nitrosamines in drinking waters are Environmental Protection Agency (EPA) Methods 522 and 521...
متن کاملDetermination of 1,4-dioxane in Drinking Water by Solid Phase Extraction (spe) and Gas Chromatography/ Mass Spectrometry (gc/ms) with Selected Ion
متن کامل
Determination of 1,4-dioxane in Drinking Water by Solid Phase Extraction (spe) and Gas Chromatography/mass Spectrometry (gc/ms) with Selected Ion Monitoring (sim)
متن کامل
Impurity analysis of 1,4-dioxane in nonionic surfactants and cosmetics using headspace solid-phase microextraction coupled with gas chromatography and gas chromatography-mass spectrometry.
1,4-Dioxane impurity in nonionic surfactants and cosmetics were analyzed using solid-phase microextraction (SPME) coupled with gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). Experimental results show that there is no significant difference using SPME-GC and SPME-GC-MS for analysis of 1,4-dioxane in three types of nonionic surfactants at the 95% confidence level. The r...